Why the study?
Conduction system pacing has emerged as an alternative to biventricular pacing in patients undergoing atrioventricular node ablation, but a comprehensive summary comparing their clinical outcomes was needed.
Does conduction system pacing improve clinical and echocardiographic outcomes compared to biventricular pacing in patients with atrial fibrillation undergoing atrioventricular node ablation?
Does conduction system pacing improve clinical and echocardiographic outcomes compared to biventricular pacing in patients with atrial fibrillation undergoing atrioventricular node ablation?
Conduction system pacing is a safe and feasible alternative to biventricular pacing in patients undergoing an AV node pace and ablate strategy, offering narrower QRS duration and improved symptomatic outcomes.
Answers are grounded in this paper and cite their sources.
Supports conduction system pacing over biventricular pacing for AF post-AVNA; extends Level 1 evidence for this strategy.
AIMS: Atrioventricular node ablation (AVNA) with permanent pacemaker implantation is an established rate-control treatment approach for patients with AF with uncontrolled ventricular rates. Conduction system pacing (CSP) utilizing His bundle pacing (HBP) or left bundle branch area pacing (LBBAP) has advanced as a treatment alternative to standard right ventricular pacing in addition to biventricular pacing (BVP). This systematic review and meta-analysis aim to provide a comprehensive summary and evaluation of clinical outcomes in the literature for CSP in comparison to BVP in conjunction with AVNA. METHODS AND RESULTS: This study protocol was registered in the PROSPERO registry (CRD42024510974), and the review was conducted as per the PRISMA guidelines. Databases were searched for relevant studies from inception till 11 January 2024. Results were synthesized using a random effects meta-analysis. From a total of 259 references identified, 122 full texts were assessed, and 25 studies were included in the systematic review. Of these included studies, five were used for comparative meta-analysis. A total of 1652 (HBP 1069 and LBBAP 644) and 369 patients received CSP and BVP implantation with AVNA, respectively. Conduction system pacing resulted in a narrower QRS duration (QRSd) with a change of -35.8 ms (95% CI -61.8 to -9.72; P < 0.05; I2 = 96.3%) vs. BVP. Conduction system pacing also resulted in better symptomatic improvement in from of NYHA reduction (MD -0.53, 95% CI -1.01 to -0.04, I2 = 62.1; P = 0.03). For left ventricular ejection fraction, a non-significant weighted mean increases of 3.36% (95% CI -0.75-7.47%; P = 0.11, I2 = 68.5%) was observed following CSP implantation in comparison to BVP. Conduction system pacing showed no significant differences in procedural and fluoroscopy times and had comparable periprocedural complications. His bundle pacing demonstrated a non-significant reduction in the events of acute threshold elevation in comparison to BVP (Log odds ratio -0.69, 95% CI -2.05-0.66, I2 = 0.00; P = 0.32). CONCLUSION: Conduction system pacing with AVNA is a safe and feasible treatment option for symptomatic (AF) patients undergoing a pace and ablate strategy, offering an alternative to BVP. Overall, CSP results in a narrower QRS duration while providing comparable clinical and echocardiographic outcomes.
No takes yet. Share an insight, caveat, or question.
Mavilakandy et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: