Why the study?
Enhanced cooling properties of the novel POLARx cryoballoon ablation system may damage adjacent tissues, leaving the prevalence and predictors of gastric hypomotility after PVI and LA roofline ablation unclear.
Does adding left atrial roofline ablation to pulmonary vein isolation using the POLARx cryoballoon increase the risk of gastric hypomotility in patients with atrial fibrillation?
Does adding left atrial roofline ablation to pulmonary vein isolation using the POLARx cryoballoon increase the risk of gastric hypomotility in patients with atrial fibrillation?
Adding left atrial roofline ablation to pulmonary vein isolation using the POLARx cryoballoon increases the risk of gastric hypomotility, particularly when the esophagus is less than 20 mm from the vertebral body midpoint.
Roofline ablation was associated with higher gastric hypomotility; leaves open whether esophageal distance should guide cryoballoon strategies.
BACKGROUND: The novel POLARx cryoballoon ablation (CBA) system offers enhanced cooling properties for the treatment of atrial fibrillation (AF); however, these capabilities may damage adjacent tissues. This study aimed to assess the prevalence and predictors of gastric hypomotility (GH) in patients undergoing pulmonary vein isolation (PVI) and left atrial (LA) roofline ablation using the POLARx. METHODS: Patients who underwent CBA for PVI using the POLARx system were included in this study. Additional LA roofline ablation was performed in patients with non-paroxysmal AF and paroxysmal AF with LA enlargement. GH occurrence was assessed postoperatively by esophagogastroscopy, and the distance between the esophagus and surrounding tissues were measured. RESULTS: Among the 61 patients who underwent PVI, 22 underwent additional LA roofline ablation. GH was confirmed in 12 patients (30.8%) who underwent PVI only and 12 patients (54.5%) who underwent additional LA roofline ablation. Symptomatic GH with acute gastric dilation occurred in three patients, all of whom had undergone roofline ablation. Multivariate analysis, a shorter distance between the esophagus and the midpoint of the vertebral body (odds ratio, 0.74; 95% confidence interval, 0.55-0.98; p = 0.04) was identified as the sole predictor of GH, with a cutoff of 20.0 mm (sensitivity, 80.0%; specificity, 81.8%). CONCLUSION: Adding LA roofline ablation to PVI using the POLARx may increase the risk of GH, particularly when the esophagus is in close proximity to the midpoint of the vertebral body.
No takes yet. Share an insight, caveat, or question.
Oda et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: