Why the study?
The Sentinel cerebral embolic protection device aims to reduce stroke risk during TAVR, but its efficacy across randomized and propensity score-matched studies needed evaluation.
Does the Sentinel cerebral embolic protection device reduce stroke in patients undergoing transcatheter aortic valve replacement?
Does the Sentinel cerebral embolic protection device reduce stroke in patients undergoing transcatheter aortic valve replacement?
The use of the Sentinel cerebral embolic protection device during TAVR significantly reduces the risk of any stroke and disabling stroke.
Answers are grounded in this paper and cite their sources.
Supports Sentinel CEP in TAVR to lower stroke risk; reinforces benefit in Level 1 meta-analysis.
BACKGROUND: The Sentinel cerebral embolic protection device (CEP) aims to reduce the risk of stroke during transcatheter aortic valve replacement (TAVR). We performed a systematic review and meta-analysis of propensity score matched (PSM) and randomized controlled trials (RCT) investigating the effect of the Sentinel CEP to prevent strokes during TAVR. METHODS: Eligible trials were searched through PubMed, ISI Web of science databases, Cochrane database, and proceedings of major congresses. Primary outcome was stroke. Secondary outcomes included all-cause mortality, major or life-threatening bleeding, major vascular complications and acute kidney injury at discharge. Fixed and random effect models were used to calculate the pooled risk ratio (RR) with 95% confidence intervals (CI) and absolute risk difference (ARD). RESULTS: A total of 4066 patients from 4 RCTs (3'506 patients) and 1 PSM study (560 patients) were included. Use of Sentinel CEP was successful in 92% of patients and was associated with a significantly lower risk of stroke (RR: 0.67, 95% CI: 0.48-0.95, p = 0.02. ARD: -1.3%, 95% CI: -2.3 - -0.2, p = 0.02, number needed to treat (NNT) = 77), and a reduced risk of disabling stroke (RR: 0.33, 95% CI: 0.17-0.65. ARD: -0.9%, 95% CI: -1.5 - -0.3, p = 0.004, NNT = 111). Use of Sentinel CEP was associated with a lower risk of major or life-threatening bleeding (RR: 0.37, 95% CI: 0.16-0.87, p = 0.02). Risk for nondisabling stroke (RR: 0.93, 95% CI: 0.62-1.40, p = 0.73), all-cause mortality (RR: 0.70, 95% CI: 0.35-1.40, p = 0.31), major vascular complications (RR: 0.74, 95% CI: 0.33-1.67, p = 0.47) and acute kidney injury (RR: 0.74, 95% CI: 0.37-1.50, p = 0.40) were similar. CONCLUSIONS: The use of CEP during TAVR was associated with lower risks of any stroke and disabling stroke with an NNT of 77 and 111, respectively.
No takes yet. Share an insight, caveat, or question.
Wolfrum et al. (2023) studied this question.