Why the study?
Coronary endothelial dysfunction represents an early stage of atherosclerosis, prompting investigation into reactive hyperemia peripheral arterial tonometry (RH-PAT) as a noninvasive tool to identify patients with coronary microvascular endothelial dysfunction.
Does reactive hyperemia peripheral arterial tonometry (RH-PAT) identify coronary microvascular endothelial dysfunction in patients without obstructive coronary artery disease?
Does reactive hyperemia peripheral arterial tonometry (RH-PAT) identify coronary microvascular endothelial dysfunction in patients without obstructive coronary artery disease?
RH-PAT provides a noninvasive method with 80% sensitivity and 85% specificity to identify early coronary atherosclerosis via microvascular endothelial dysfunction.
Answers are grounded in this paper and cite their sources.
May enable noninvasive detection of coronary microvascular endothelial dysfunction; leaves open routine adoption pending larger prospective validation.
OBJECTIVES: We investigated the value of reactive hyperemia peripheral arterial tonometry (RH-PAT) as a noninvasive tool to identify individuals with coronary microvascular endothelial dysfunction. BACKGROUND: Coronary endothelial dysfunction, a systemic disorder, represents an early stage of atherosclerosis; RH-PAT is a technique to assess peripheral microvascular endothelial function. METHODS: Using RH-PAT, digital pulse volume changes during reactive hyperemia were assessed in 94 patients without obstructive coronary artery disease and either normal (n = 39) or abnormal (n = 55) coronary microvascular endothelial function; RH-PAT index, a measure of reactive hyperemia, was calculated as the ratio of the digital pulse volume during reactive hyperemia divided by that at baseline. RESULTS: Average RH-PAT index was lower in patients with coronary endothelial dysfunction compared with those with normal coronary endothelial function (1.27 +/- 0.05 vs. 1.78 +/- 0.08: p < 0.001). An RH-PAT index <1.35 was found to have a sensitivity of 80% and a specificity of 85% to identify patients with coronary endothelial dysfunction. CONCLUSIONS: Digital hyperemic response, as measured by RH-PAT, is attenuated in patients with coronary microvascular endothelial dysfunction, suggesting a role for RH-PAT as a noninvasive test to identify patients with this disorder.
No takes yet. Share an insight, caveat, or question.
Bonetti et al. (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: