Why the study?
Little literature has reported on escape rhythms occurring after TAVI.
An invasive electrophysiology study is useful for delineating conduction system disturbances, such as infra-nodal AV block masked by an accelerated infra-Hisian escape rhythm, following TAVI.
Answers are grounded in this paper and cite their sources.
May warrant targeted post-TAVI EPS to detect masked infra-nodal block; leaves open whether routine use improves outcomes.
An 83-year-old woman underwent transcatheter aortic valve implantation (TAVI) using SAPIEN 3 23-mm valve (Edwards Lifesciences, Irvine, CA) for severe aortic valve stenosis in our hospital. Her preprocedural surface electrocardiogram (sECG) showed a right bundle branch block (RBBB) with a normal axis (Figure 1A: heart rate = 74 bpm, PR = 198 ms, QRS = 140 ms). Shortly after the successful TAVI, she developed an escape rhythm (ER) with atrioventricular dissociation and RBBB with left axis deviation (Figure 1B: ventricular rate = 65 bpm, atrial rate = 59 bpm, QRS = 142 ms). The ER was still persistent even on the third postoperative day. We suspected the ER was due to the conduction system injury, but the ER itself disturbed the evaluation of atrioventricular conduction on sECG. Therefore, an electrophysiology study (EPS) was performed. During the ER and atrial overdrive pacing, an infra-nodal atrioventricular block (intra-or infra-Hisian block) was unveiled (Figures 1C and 1D), and the ER was not suppressed by 40 mg of adenosine triphosphate. Therefore, she was diagnosed with accelerated infra-Hisian escape rhythm. Since the prognosis of this rhythm was unclear, we performed DDD pacemaker implantation. Little literature reported on the ER occurring after TAVI.1Angsubhakorn N. Akdemir B. Bertog S. Garcia S. Vutthikraivit W. Adabag S. Junctional rhythm following transcatheter aortic valve replacement.HeartRhythm Case Reports. 2020; 6: 749-753Abstract Full Text Full Text PDF Scopus (0) Google Scholar To the best of our knowledge, this is the first report of the persistent accelerated infra-Hisian escape rhythm concomitant with infra-nodal atrioventricular block after TAVI, which was demonstrated by an invasive EPS. In this case, the ER with atrioventricular dissociation masked comorbid infra-nodal atrioventricular block and revealed an infra-Hisian origin rather than an atrioventricular nodal escape rhythm with the aberrant conduction, despite having a similar QRS duration to the baseline. In such a situation, an EPS for evaluating atrioventricular conduction should be considered to investigate the conduction system disturbance. ●Accelerated infra-Hisian escape rhythm after transcatheter aortic valve implantation can mask infra-nodal atrioventricular block.●An invasive electrophysiology study is useful for delineating such a condition. We appreciate our hospital’s clinical engineers. Data availability The data will not be shared.
No takes yet. Share an insight, caveat, or question.
Sekihara et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: