Why the study?
S-ICD generator size and implantation near the left breast may cause discomfort and issues with self-perception and sexuality in women, but female-specific experiences and practical guidance were lacking.
What are the gender-specific issues and discomforts experienced by female patients with a subcutaneous implantable cardioverter-defibrillator (S-ICD)?
What are the gender-specific issues and discomforts experienced by female patients with a subcutaneous implantable cardioverter-defibrillator (S-ICD)?
Female S-ICD patients frequently experience significant device-related discomfort, postoperative pain, and intimacy issues, highlighting the need for adequate counseling and implanter awareness.
Answers are grounded in this paper and cite their sources.
May prompt counseling on discomfort for female S-ICD patients; hypothesis-generating for optimal generator positioning.
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) consists of a large generator and is implanted near the left breast. This might lead to discomfort and problems with self-perception and sexuality, especially in the female population. We aimed to assess the issues that female S-ICD patients experience and to provide practical guidance for cardiologists and implanters on minimizing these issues. METHODS: For this retrospective single-center study, we conducted semi-structured interviews with four female S-ICD patients and processed their experiences into a questionnaire. This consisted of three open questions and 17 statements that participants could answer through a five-point Likert scale. The questionnaire was subsequently sent to all female adult patients who received an S-ICD between February 2009 and November 2018 in our tertiary centre in Amsterdam, the Netherlands. RESULTS: The response rate of the questionnaire was 73%, with 52 female respondents (mean age 47.4 ± 12.5 years, mean time since implant 4.6 ± 3.1 years). Postoperative pain exceeded the expectation of 54% of the respondents. Furthermore, 14 out of 49 respondents (29%) expressed an unpleasant feeling during intimate contact with their sexual partner since the implant. Many women (44%) reported daily discomfort caused by their bra and preferred a more cranial and posterior position of the S-ICD generator. Finally, a smaller design of the generator is desired by a great majority (63%) of female S-ICD patients CONCLUSION: Female S-ICD patients experience a variety of issues with a substantial impact on their daily life. Most issues that we identified would benefit from adequate counseling and implanter awareness.
No takes yet. Share an insight, caveat, or question.
Stuijt et al. (2020) studied this question.