Why the study?
Does high implantation depth reduce elevated postprocedural gradients in patients undergoing transcatheter valve-in-valve replacement for failed bioprosthetic valves?
Does high implantation depth reduce elevated postprocedural gradients in patients undergoing transcatheter valve-in-valve replacement for failed bioprosthetic valves?
Answers are grounded in this paper and cite their sources.
High implantation depth during transcatheter valve-in-valve procedures significantly reduces the risk of elevated postprocedural gradients compared to low implantation.
BACKGROUND: Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets for implantation that would improve hemodynamics after ViV. METHODS AND RESULTS: Cases from the Valve-in-Valve International Data (VIVID) registry were analyzed using centralized core laboratory assessment blinded to clinical events. Multivariate analysis was performed to identify independent predictors of elevated postprocedural gradients (mean ≥20 mm Hg). Optimal implantation depths were defined by receiver operating characteristic curve. A total of 292 consecutive patients (age, 78.9±8.7 years; 60.3% male; 157 CoreValve Evolut and 135 Sapien XT) were evaluated. High implantation was associated with significantly lower rates of elevated gradients in comparison with low implantation (CoreValve Evolut, 15% versus 34.2%; P=0.03 and Sapien XT, 18.5% versus 43.5%; P=0.03, respectively). Optimal implantation depths were defined: CoreValve Evolut, 0 to 5 mm; Sapien XT, 0 to 2 mm (0-10% frame height); sensitivities, 91.3% and 88.5%, respectively. The strongest independent correlate for elevated gradients after ViV was device position (high: odds ratio, 0.22; confidence interval, 0.1-0.52; P=0.001), in addition to type of device used (CoreValve Evolut: odds ratio, 0.5; confidence interval, 0.28-0.88; P=0.02) and surgical valve mechanism of failure (stenosis/mixed baseline failure: odds ratio, 3.12; confidence interval, 1.51-6.45; P=0.002). CONCLUSIONS: High implantation inside failed bioprosthetic valves is a strong independent correlate of lower postprocedural gradients in both self- and balloon-expandable transcatheter valves. These clinical evaluations support specific implantation targets to optimize hemodynamics after ViV.
No takes yet. Share an insight, caveat, or question.
Simonato et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: