Why the study?
Smartwatch ECGs could facilitate the detection of sudden cardiac arrest-associated abnormalities, but their feasibility and agreement with 12-lead ECGs in young adults required evaluation.
Does a smartwatch ECG accurately detect abnormalities associated with sudden cardiac arrest compared to a 12-lead ECG in young adults?
Does a smartwatch ECG accurately detect abnormalities associated with sudden cardiac arrest compared to a 12-lead ECG in young adults?
A smartwatch ECG, particularly when utilizing chest positions, can effectively detect ECG abnormalities associated with sudden cardiac arrest in young adults.
Answers are grounded in this paper and cite their sources.
May aid ECG screening in young adults; leaves open prospective validation for sudden cardiac arrest risk detection.
AIMS: Smartwatch electrocardiograms (ECGs) could facilitate the detection of sudden cardiac arrest (SCA)-associated abnormalities. We evaluated the feasibility of using smartwatch-derived ECGs for detecting SCA-associated abnormalities in young adults and its agreement with 12-lead ECGs. METHODS AND RESULTS: Twelve-lead and Apple Watch ECGs were registered in 155 healthy volunteers and 67 patients aged 18-45 years with diagnosis and ECG signs of long-QT syndrome (n = 10), Brugada syndrome (n = 12), ventricular pre-excitation (n = 19), hypertrophic cardiomyopathy (HCM, n = 13), and arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVC/D, n = 13). Cardiologists separately analysed 12-lead ECGs and the smartwatch ECGs taken from the left wrist (AW-I) and then from chest positions V1, V3, and V6 (AW-4). Compared with AW-I, AW-4 improved the classification of ECGs as 'abnormal', increasing the sensitivity from 64% to 89% (P < 0.01). Pre-excitation was detected in most cases using AW-I (sensitivity 89%) and in all cases using AW-4 (sensitivity 100%, P = 0.48 compared with AW-I, specificity 100% for both). Brugada was missed using AW-I but was detected in 11/12 patients using AW-4 (sensitivity 92%, specificity 100%, P = 0.003). Long QT was detected in 8/10 cases using AW-I (sensitivity 80%, specificity 100%) and in 9 patients using AW-4 (sensitivity 90%, specificity 100%, P > 0.99). Hypertrophic cardiomyopathy was correctly suspected using AW-I and AW-4 (sensitivity 92% and 85%, specificity 85%, and 100%, P > 0.99). AW-I was mostly (62%) considered normal in ARVC/D whereas AW-4 was useful in suspecting ARVC/D (100% sensitivity, 99% specificity, P = 0.004). CONCLUSIONS: Detection of SCA-associated ECG abnormalities (pre-excitation, Brugada patterns, long QT, and signs suggestive of HCM and ARVC/D) is possible with an ECG smartwatch.
No takes yet. Share an insight, caveat, or question.
Nasarre et al. (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: