Why the study?
In CMR cine imaging by compressed sensing, the required steady-state free-precession preparation cycle extends breath-hold duration to an impractical length for patients unable to tolerate long breath-holding.
Does the 'single-cycle-stack-advance' compressed-sensing cine method provide reliable biventricular volume analysis compared to conventional SSFP cines in pediatric patients?
Does the 'single-cycle-stack-advance' compressed-sensing cine method provide reliable biventricular volume analysis compared to conventional SSFP cines in pediatric patients?
The single-cycle-stack-advance compressed-sensing CMR method halves breath-hold duration while providing reliable biventricular volumetric analysis in pediatric patients.
Answers are grounded in this paper and cite their sources.
Supports shorter breath-hold cine for reliable pediatric biventricular EF; leaves open prospective validation before routine adoption.
OBJECTIVES: Cardiovascular magnetic resonance (CMR) cine imaging by compressed sensing (CS) is promising for patients unable to tolerate long breath-holding. However, the need for a steady-state free-precession (SSFP) preparation cardiac cycle for each slice extends the breath-hold duration (e.g. for 10 slices, 20 cardiac cycles) to an impractical length. We investigated a method reducing breath-hold duration by half and assessed its reliability for biventricular volume analysis in a pediatric population. METHODS: Fifty-five consecutive pediatric patients (median age 12 years, range 7-17) referred for assessment of congenital heart disease or cardiomyopathy were included. Conventional multiple breath-hold SSFP short-axis (SAX) stack cines served as the reference. Real-time CS SSFP cines were applied without the steady-state preparation cycle preceding each SAX cine slice, accepting the limitation of omitting late diastole. The total acquisition time was 1 RR interval/slice. Volumetric analysis was performed for conventional and "single-cycle-stack-advance" (SCSA) cine stacks. RESULTS: Bland-Altman analyses [bias (limits of agreement)] showed good agreement in left ventricular (LV) end-diastolic volume (EDV) [3.6 mL (- 5.8, 12.9)], LV end-systolic volume (ESV) [1.3 mL (- 6.0, 8.6)], LV ejection fraction (EF) [0.1% (- 4.9, 5.1)], right ventricular (RV) EDV [3.5 mL (- 3.34, 10.0)], RV ESV [- 0.23 mL (- 7.4, 6.9)], and RV EF [1.70%, (- 3.7, 7.1)] with a trend toward underestimating LV and RV EDVs with the SCSA method. Image quality was comparable for both methods (p = 0.37). CONCLUSIONS: LV and RV volumetric parameters agreed well between the SCSA and the conventional sequences. The SCSA method halves the breath-hold duration of the commercially available CS sequence and is a reliable alternative for volumetric analysis in a pediatric population. KEY POINTS: • Compressed sensing is a promising accelerated cardiovascular magnetic resonance imaging technique. • We omitted the steady-state preparation cardiac cycle preceding each cine slice in compressed sensing and achieved an acquisition speed of 1 RR interval/slice. • This modification called "single-cycle-stack-advance" enabled the acquisition of an entire short-axis cine stack in a single short breath hold. • When tested in a pediatric patient group, the left and right ventricular volumetric parameters agreed well between the "single-cycle-stack-advance" and the conventional sequences.
No takes yet. Share an insight, caveat, or question.
Hatipoğlu et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: