Why the study?
Early identification of healthy individuals prone to cardiac dysfunction may guide prevention, but whether GDF-15 predicts long-term adverse changes in cardiac structure and function remained unknown.
Are circulating GDF-15 levels associated with early echocardiographic signs of diastolic function impairment in an initially healthy population?
Are circulating GDF-15 levels associated with early echocardiographic signs of diastolic function impairment in an initially healthy population?
Answers are grounded in this paper and cite their sources.
Higher baseline GDF-15 levels in an initially healthy population predict echocardiographic signs of diastolic dysfunction nearly two decades later, suggesting its potential as a screening tool.
AIMS: Early identification of healthy subjects prone to develop cardiac dysfunction may be instrumental to prevention strategies. Our study aimed to evaluate whether circulating levels of growth differentiation factor-15 (GDF-15) could predict adverse changes in echocardiographic indexes of cardiac structure and function in an initially healthy populational familial cohort with a long follow-up (STANISLAS cohort). METHODS AND RESULTS: We evaluated 1679 participants (49 ± 14 years, 48% males) included in the fourth visit (V4) of the STANISLAS cohort with available GDF-15 measurements (Olink proteomic analysis) and echocardiographic parameters. Among them, 1562 had also GDF-15 measurements at the first visit (V1) (18.2 ± 1.4 years before V4). We evaluated both prospective (GDF-15 at V1) and cross-sectional (GDF-15 at V4) associations between GDF-15 levels and echocardiographic variables. In adjusted analyses, higher baseline GDF-15 levels were associated with lower left ventricular (LV) end-diastolic volume and higher E/e' ratio nearly two decades later (both p ≤ 0.01). The cross-sectional analysis at V4 also found significant associations between GDF-15 and LV end-diastolic volume and higher E/e' ratio, further identifying significant associations with impaired LV strain. CONCLUSION: In the STANISLAS cohort, initial circulating GDF-15 levels were associated with echocardiographic signs of reduced LV size and increased filling pressure almost two decades later. This association was also confirmed by evaluating GDF-15 at the follow-up visit (V4). These findings suggest a potential role for GDF-15 as an easy screening and prognostic tool of diastolic dysfunction in the general population.
No takes yet. Share an insight, caveat, or question.
Monzo et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: