Why the study?
The study sought to assess the need for permanent pacemaker implantation in patients with QRS <120 ms on ECG after TAVI.
Does a normal QRS duration (<120 ms) immediately after TAVI predict a low risk of complete AV block and need for permanent pacemaker implantation?
Does a normal QRS duration (<120 ms) immediately after TAVI predict a low risk of complete AV block and need for permanent pacemaker implantation?
Patients with a normal QRS duration (<120 ms) immediately after TAVI have a very low risk of developing complete AV block, suggesting that prolonged rhythm monitoring may not be necessary for this subgroup.
Answers are grounded in this paper and cite their sources.
Normal post-TAVI QRS may support shorter monitoring in low-risk patients; hypothesis-generating and requires prospective validation.
AIMS: We sought to assess the need for permanent pacemaker implantation (PPI) in patients with QRS <120 ms in electrocardiogram (ECG) after transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: We retrospectively analysed 1139 consecutive patients who underwent transfemoral TAVI between 2008 and 2016, receiving different valve types. All patients were surveyed by continuous ECG monitoring for 48 h, 12-lead ECGs starting immediately after procedure, as well as 24-h Holter recording the day before discharge. Indication for PPI was at the discretion of the attending physician. Among 760 patients with QRS <120 ms prior to the TAVI procedure, 400 patients showed QRS <120 ms immediately after procedure, whereas 360 patients had QRS ≥120 ms. In the group with QRS <120 ms, PPI was performed in 34 patients [8.5%; 95% confidence interval (CI) 5.6-11.2%] during the first week. Eight of the PPIs in the group with QRS <120 ms (2%; CI 0.8-3.5%) fulfilled Class I indications for PPI after TAVI, whereas 26 PPIs had different indications [left bundle branch block, sick sinus, low-grade atrioventricular (AV) block]. Complete AV block developed in three patients of the group of QRS <120 ms (0.75%; CI 0.0-1.7%), which in all cases occurred after the 48 h-surveillance period. During 1-year follow-up, 11 PPIs were performed (2.8%; CI 1.2-4.5%), thereof three PPI for Class I indications including one complete AV block. CONCLUSION: In patients with QRS duration <120 ms immediately after TAVI, the risk for complete AV block was low during the first week after TAVI and 1-year follow-up.
No takes yet. Share an insight, caveat, or question.
Schoechlin et al. (2019) studied this question.