Why the study?
Data on prosthesis-patient mismatch after TAVR derived mainly from older generation valves, leaving the impact of next-generation self-expanding and balloon-expandable valves unclear.
Does the use of next-generation transcatheter heart valves compared to older generation valves affect the incidence of prosthesis-patient mismatch in patients undergoing TAVR?
Does the use of next-generation transcatheter heart valves compared to older generation valves affect the incidence of prosthesis-patient mismatch in patients undergoing TAVR?
Next-generation transcatheter heart valves, particularly balloon-expandable valves without adequate oversizing, are associated with a higher incidence of prosthesis-patient mismatch compared to older generation valves.
Answers are grounded in this paper and cite their sources.
Next-generation THVs were associated with higher PPM rates; leaves open optimal sizing and valve selection strategies in TAVR.
OBJECTIVES: To investigate the impact of the introduction of the next generation self-expanding (SE) and balloon-expandable (BE) transcatheter heart valves (THVs) on the incidence of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR). BACKGROUND: PPM is a risk factor for accelerated degeneration of bioprosthetic aortic valves. Data on PPM after TAVR are derived mainly from studies of older generation THVs. METHODS: PPM was assessed at 30 days post-TAVR with the older generation (Medtronic CoreValve, n = 120 and Edwards Sapien XT, n = 121) and the next generation THVs (Medtronic Evolut R/Pro, n = 136 and Edwards Sapien 3, n = 363). RESULTS: The incidence of any and severe PPM was 15.1% and 0.0% for the older generation THVs, and 42.8% and 12.1% for the next generation THVs. The incidence of moderate and severe PPM was 23.3% and 3.5% in patients who received an Evolut R/Pro vs. 33.1% and 14.7% in those who received a Sapien 3 (P < 0.001). On multivariable analysis, TAVR with the Sapien 3 THV was not associated with PPM, while left ventricular ejection fraction (0.97 [0.95-0.99], P = 0.002), history of myocardial infarction (2.09 [1.00-4.34], P = 0.049), annulus maximum diameter (0.84 [0.77-0.92], P < 0.001), and THV oversizing (0.90 [0.87-0.94], P < 0.001) were independently associated with PPM. In Sapien 3, the risk of any and severe PPM was higher in those with no oversizing (odds ratio: 3.25 [1.23-8.53], P = 0.017 and 5.79[2.33-14.36], P < 0.001). CONCLUSIONS: The incidence of PPM in contemporary TAVR is significant, especially with the next generation BE THV without adequate oversizing.