Why the study?
Does three-dimensional transesophageal echocardiography (3DTEE) correlate with multi-detector computed tomography (MDCT) for aortic annular sizing in patients undergoing pre-TAVR assessment?
Does three-dimensional transesophageal echocardiography (3DTEE) correlate with multi-detector computed tomography (MDCT) for aortic annular sizing in patients undergoing pre-TAVR assessment?
3DTEE demonstrates a high level of correlation with MDCT for aortic annulus measurements, making it a feasible, contrast-free, and radiation-free alternative for pre-TAVR assessment.
Answers are grounded in this paper and cite their sources.
Supports 3DTEE as a contrast- and radiation-free alternative for pre-TAVR sizing; extends meta-analytic evidence of MDCT concordance.
BACKGROUND: Cardiac imaging is the cornerstone of the pretranscatheter aortic valve replacement (TAVR) assessment. Multi-detector computed tomography (MDCT) is considered the conventional imaging modality. However, there is still no definitive gold standard. Targeted cohort of inoperable high-risk patients with underlying comorbidities, particularly renal impairment, makes apparent the need for MDCT alternative. We aimed to demonstrate the correlation extent between MDCT and three-dimensional transesophageal echocardiography (3DTEE) aortic annular area measures and to answer the question: Is 3DTEE a good alternative to MDCT? METHODS: A systematic literature search and meta-analysis were conducted to evaluate the degree of correlation and agreement between 3DTEE and MDCT aortic annular sizing. A thorough assessment of EMBASE, PubMed, and Cochrane Central Register of Controlled Trials (CENTRAL) was performed. All studies comparing 3DTEE and MDCT in relation to aortic annular sizing were included. RESULTS: with 95% limits of agreement -12.79 to 8.36. CONCLUSION: Aortic annulus measurements obtained by 3DTEE demonstrated a high level of correlation with those evaluated by MDCT. This makes 3DTEE a feasible choice for aortic annulus assessment, with advantage of real time assessment, lack of contrast, and no radiation exposure.
No takes yet. Share an insight, caveat, or question.
Elkaryoni et al. (2018) studied this question.