Why the study?
Does cross-sectional short axis 2D-TEE reduce the incidence of significant post-procedural aortic regurgitation compared to long axis 2D-TEE in patients undergoing TAVI?
Does cross-sectional short axis 2D-TEE reduce the incidence of significant post-procedural aortic regurgitation compared to long axis 2D-TEE in patients undergoing TAVI?
Sizing the aortic annulus using cross-sectional short axis 2D-TEE significantly reduces the incidence of significant post-procedural aortic regurgitation compared to long axis 2D-TEE in patients undergoing TAVI with self-expandable prostheses.
Answers are grounded in this paper and cite their sources.
Short-axis 2D-TEE sizing was associated with less post-TAVI AR; hypothesis-generating and should not yet change practice.
BACKGROUND: Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we validated a new method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus prior to TAVI. METHODS: We analysed 124 patients who underwent successful TAVI using a self-expandable prosthesis, divided equally into two groups; in the study group we used the cross sectional short axis 2D-TEE for measurement of the aortic annulus and in the control group we used the long axis 2D-TEE. RESULTS: Both groups were comparable regarding the clinical parameters. On the other hand, patients in the study group had less left ventricular ejection fraction (38.9 % versus 45.6 %, p = 0.01). The aortic valve annulus was, although not statistically significant, smaller in the study group (21.58 versus 23.28 mm, p = 0.25). Post procedural quantification of the aortic regurgitation revealed that only one patient in both groups had severe aortic regurgitation (AR), in this patient the valve was implanted deep. The incidence of significant AR was higher in the control group (29.0 % versus 12.9 %, p = 0.027). CONCLUSIONS: Sizing of the aortic valve annulus using cross-sectional 2D-TEE offers a safe and plausible method for patients undergoing TAVI using the self-expandable prosthesis and is significantly superior to using long axis 2D-TEE.
No takes yet. Share an insight, caveat, or question.
Sherif et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: