In-vitro study shows improved prosthetic abutment fit in guided implant placement using a bone leveler, suggesting enhanced clinical protocols.
PURPOSE: Guided sub-crestal implant placement is limited by the lack of visual confirmation, making abutment connection dependent on tactile feedback, which may be compromised by residual bone at the implant crest. A bone leveler can remove excess bone above the implant platform, but no clinical guidelines exist for its use in guided sub-crestal surgery. This in-vitro study evaluated the effect of a bone leveler on prosthetic abutment fit. MATERIALS AND METHODS: Ten 3D-printed artificial bone models with irregular cortical morphology were prepared using CAD-CAM technologies from a micro-CT scan obtained from the NIH 3D Print Exchange. Sleeveless surgical guides were digitally designed and additively manufactured, and a 3-mm polyvinyl siloxane layer simulated soft tissue. Guided osteotomies for four implants per model (N = 40) were performed using two protocols: conventional drilling (Control) and conventional drilling plus a bone leveler (Test). Abutments were hand-tightened and assessed for seating by two blinded clinicians through tactile and radiographic evaluation. Inter-rater agreement was quantified via Cohen's Kappa, and Chi-square tests evaluated the effect of the bone leveler on seating outcomes. RESULTS: All abutments were deemed fully seated by tactile assessment of Clinician 1. Independent blinded tactile assessment by Clinician 2 confirmed 80% of abutments in Controls and 85% in Tests as fully seated. Radiographic evaluation revealed 80% fully seated abutments in Test versus only 15% in Controls. The difference was statistically significant (χ² = 7.27, p = 0.007). Inter-rater agreement between tactile and radiographic assessments was poor (C1 vs C2: Kappa = 0; C2 vs R: Kappa = -0.10), highlighting that tactile assessment alone is unreliable. Implants placed in osteotomies prepared with a bone leveler consistently achieved complete abutment seating, whereas those placed without a bone leveler frequently exhibited gaps and were often misclassified as properly fitted. CONCLUSIONS: Within the limitations of this in vitro study, incorporating a bone leveler in guided sub-crestal implant placement significantly improves prosthetic abutment fit. Its use should be considered a prerequisite in clinical protocols to enhance prosthetic abutment seating accuracy and improve predictability in guided implant therapy.
No takes yet. Share an insight, caveat, or question.
Nahm et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: