Answers are grounded in this paper and cite their sources.
Evaluates moisture, pH, and temperature in feedlot pens, indicating thermal image sensitivity varies by location.
The study evaluated spatial variation in feedlot pen-surface moisture, pH, and temperature as well as assessed if measurements could be detected using unmanned aerial vehicle (UAV) thermal imagery. The objectives were to (1) characterize pen-surface moisture, pH, and temperature across the pen landscape, and (2) evaluate associations between UAV thermal images and pen-surface moisture, pH, and temperature. Three dirt-floor pens (30 x 60 m, n = 3) near Minneola, Kansas each housed 42 ± 3 head cattle (body weight 269.1 ± 4.2 kg) fed a common limit-fed growing ration. Pens were divided into 12 quadrants, representing distinct pen regions (e.g., concrete apron, fenceline, waterer, etc.). On a single summer day from 1230 to 1300 hours, 30 g pen-surface grab samples were collected in triplicate from each quadrant, composited, and analyzed for pH and moisture. Pen-surface temperature was also measured in triplicate in each quadrant using an infrared thermometer. During the time of sample collection, an UAV (AUTEL EVO 2) equipped with a thermal sensor (H20T) was flown at 30 m altitude to capture images. Images were processed with Pix4D, visualized with ArcGIS, and color metrics were obtained in Adobe Photoshop. Pen-surface moisture, pH and temperature were analyzed using linear mixed models with fixed effect of quadrant and random effect of pen. Color values from UAV thermal images were analyzed for association to pen-surface characteristics using linear mixed models with fixed effects of color value, quadrant, and the interaction of color value by quadrant. Differences between pen-surface quadrants were observed for moisture (P = <0.01), and pH (P = <0.01) but not for temperature (P = 0.23). Heterogeneity in moisture and pH across the quadrants presented these variables as candidates to test for an association with color values from UAV thermal images. The interaction of calculated luminosity color value ([min R,G,B] + [max R,G,B]/2) and quadrant was associated with moisture (P < 0.01) but not for pH (P = 0.45). When predicting moisture from luminosity values derived from thermal images captured at 1230, the model demonstrated poor agreement between actual and predicted moisture values (Lin’s concordance correlation coefficient = 0.46). Results suggest that the thermal signal at the time of image collection lacked sufficient sensitivity to surface moisture conditions, indicating that time of UAV flight may affect thermal image sensitivity to moisture or pH conditions. Results demonstrated that pen-surface moisture and pH differed spatially and thermal imagery response to moisture was location-dependent. Data for pen-surface temperature provides evidence of a need for emissivity calibration to improve temperature measurement accuracy.
No takes yet. Share an insight, caveat, or question.
Diller et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: