Answers are grounded in this paper and cite their sources.
Retrospective protocol study aims to set local diagnostic reference levels for CT brain imaging in adults, suggesting improved radiation dose management.
Introduction: Computed Tomography (CT) brain imaging provides high-resolution anatomical detail but involves relatively higher radiation doses, necessitating dose monitoring and optimisation. Diagnostic reference levels (DRLs) are recommended dose indicators for optimising radiation exposure without compromising diagnostic image quality; however, national DRLs for CT brain imaging have not yet been established in South Africa. This article presents a protocol for establishing local DRLs for non-contrast- (non-CE) and contrast-enhanced (CE) adult CT brain examinations at an academic hospital in Johannesburg, South Africa. Materials and Methods: The research site is at a single hospital in Johannesburg, South Africa. The research design for this study is retrospective. A sample of 197 adult CT brain examinations (63 non-CE, 34 CE, and 100 combined non-CE and CE examinations) performed between 1 January and 31 December 2024 will be used to develop local DRLs. The 64-slice CT scanner of choice for data collection is the Siemens SOMATOM Definition AS. The population defined for this study is individuals aged 18–70 years. The preferred contrast media used for CT brain examination at the research site is 40 mL of Omnipaque 350. The scan range for CT brain is from the base of the skull (foramen magnum) to the vertex, ensuring full coverage of intracranial structures. Dose metrics, including the volumetric CT dose index (CTDIvol) and dose–length product (DLP), will be extracted from archived dose reports. Local DRLs will be established as the 75th percentile values of CTDIvol and DLP for each protocol group. Descriptive statistics (mean, median, and interquartile range) will be used to summarise the data demographics. The effective dose will be estimated by applying a head-specific conversion coefficient to the DLP values. Results: As this is a study protocol, results are not yet available. Local DRLs will be reported as the mean, median, and 75th percentile values of the DLP and CTDIvol for non-CE, CE, and for both non-CE and CE CT brain examinations. The effective dose will be estimated by applying a head-specific dose conversion coefficient (k-factor) to the mean DLP values. Expected Outcomes: This study is expected to establish local DRLs for adult CT brain examinations, providing baseline data for dose optimisation and supporting the future development of national DRLs in South Africa. Conclusions: Establishing local DRLs will support the optimisation of the radiation dose in CT brain imaging to keep the dose as low as reasonably achievable. The DRLs developed for this study will contribute to national and international efforts toward optimising radiation dose during diagnostic X-ray imaging investigations.
No takes yet. Share an insight, caveat, or question.
Seekoei et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: