Field analysis establishes safe application rates for flammable products in construction, suggesting improved safety guidelines.
In architecture and construction, it is common practice to use acrylic products with a high flammable content, ranging from lacquers designed to improve the curing of concrete and mortar to resins that provide protection, sealing, flexibility, and elasticity. The drying process of the treated surface involves the formation of vapours of volatile organic compounds (VOCs); to prevent these from creating a potentially hazardous flammable atmosphere, a procedure is presented that establishes the maximum application rate for solvent-based products, providing equations that relate the maximum application area and the minimum drying time to the available air velocity in the work area. The results are provided for both indoor and outdoor applications. A maximum application rate is established to prevent the creation of areas classified as fire or explosion hazards: 1.5 m2/h indoors and 1 m2/h outdoors. When this is carried out at an ambient temperature of 20 °C, and from 40 °C upwards, it is not possible to apply the varnishes in practice without creating a flammable atmosphere.
No takes yet. Share an insight, caveat, or question.
Ballesteros-Álvarez et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: