Answers are grounded in this paper and cite their sources.
A corrugated silver diaphragm-based optical fiber microphone (OFM), formed by extrinsic Fabry-Perot interferometric structure, was proposed. The sensor's sensitivity was improved by releasing diaphragm's initial stress with the help of corrugations. A simple “gray-scale exposure” method was proposed to fabricate the corrugation. Experimental results indicated that the mechanical sensitivity of the fabricated corrugated diaphragm (CD) was 52 nm/Pa, which was twice that of the planar diaphragm under the same parameters. Other characteristics of the fabricated microphone were also tested in detail. The proposed CD-based OFM showed the advantages of high sensitivity, simplicity and low cost, which was expected to be applied in the field of weak acoustic sensing.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2018) studied this question.