Demonstrates secure image transfer in telemedicine, indicating improved confidentiality and integrity.
Secure image transfer is a critical requirement in telemedicine and Picture Archiving and Communication Systems (PACS), where diagnostic integrity and patient confidentiality must be simultaneously ensured. High-resolution medical images, especially Magnetic Resonance Imaging (MRI), are often transferred over bandwidth-limited networks without impairing diagnostic quality or confidentiality against unauthorized access, manipulation, and replay. Existing approaches generally rely on a cascaded pipeline where image compression, encryption, and verification are considered as separate, independent operations. These distributed designs are prone to cryptographic key management issues, suffer from non-deterministic error control, lack meaningful coupling between image identity and cryptographic state, and provide no verifiable provenance or post-quantum key migration support. In this paper, we propose a DICOM-compliant system that integrates ϵ -regularized near-lossless image compression, hyperchaotic permutation diffusion encryption, post-quantum secure key establishment, and blockchain-based provenance verification as a unified operation. JPEG 2000 is used for primary image compression, and a residual refinement layer is introduced to limit residual correction amplitudes by ϵ -regularization to retain diagnostically significant information. Hyperchaotic encryption is performed with a symmetric image key generated using the NIST-standard post-quantum Key Encapsulation Mechanism (ML-KEM) and extracted using the HMAC-based Key Derivation Function (HKDF), cryptographically linked to DICOM image metadata. Message integrity is ensured using a keyed-hash message authentication code (HMAC), while a permissioned blockchain records only non-sensitive cryptographic metadata to enable verifiable provenance. Experimental results on clinical MRI and susceptibility-weighted imaging datasets demonstrate high reconstruction quality (PSNR: 46–51 dB, SSIM: 0.92–0.97), compression ratios ranging from 7.14:1 to 23.03:1 depending on modality and ϵ , and strong cryptographic properties (NPCR: 99.6%, UACI: 33.46%, entropy: 7.9993). The evaluation focuses on MRI-based modalities, reflecting the intended scope of this study.
No takes yet. Share an insight, caveat, or question.
Yadav et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: