Key result
Downsloping PR segments and higher P wave amplitudes distinguish false-positive from true-positive exercise tests.
Why the study?
Exaggerated atrial repolarization waves during exercise may produce ST segment depression mimicking myocardial ischemia, leading to false positive exercise tests.
Can electrocardiographic criteria involving atrial repolarization waves identify false positive exercise tests in patients with suspected ischemia?
Case-Control (n=69)
Can electrocardiographic criteria involving atrial repolarization waves identify false positive exercise tests in patients with suspected ischemia?
Answers are grounded in this paper and cite their sources.
Exaggerated atrial repolarization waves during exercise, characterized by downsloping PR segments and increased P wave amplitude, can mimic ST segment depression and help identify false positive exercise tests.
Atrial repolarization waves are opposite in direction to P waves, may have a magnitude of 100 to 200 mu V and may extend into the ST segment and T wave. It was postulated that exaggerated atrial repolarization waves during exercise could produce ST segment depression mimicking myocardial ischemia. The P waves, PR segments and ST segments were studied in leads II, III, aVF and V4 to V6 in 69 patients whose exercise electrocardiogram (ECG) suggested ischemia (100 mu V horizontal or 150 mu V upsloping ST depression 80 ms after the J point). All had a normal ECG at rest. The exercise test in 25 patients (52% male, mean age 53 years) was deemed false positive because of normal coronary arteriograms and left ventricular function (5 patients) or normal stress single photon emission computed tomographic thallium or gated blood pool scans (16 patients), or both (4 patients). Forty-four patients with a similar age and gender distribution, anginal chest pain and at least one coronary stenosis greater than or equal to 80% served as a true positive control group. The false positive group was characterized by 1) markedly downsloping PR segments at peak exercise, 2) longer exercise time and more rapid peak exercise heart rate than those of the true positive group, and 3) absence of exercise-induced chest pain. The false positive group also displayed significantly greater absolute P wave amplitudes at peak exercise and greater augmentation of P wave amplitude by exercise in all six ECG leads than were observed in the true positive group.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Sapin et al. (1991) conducted a case-control in Exercise-induced ST segment depression mimicking myocardial ischemia (n=69). False positive exercise test (exaggerated atrial repolarization waves) vs. True positive exercise test (coronary stenosis ≥80%) was evaluated on ECG and clinical characteristics during exercise (PR segment slope, P wave amplitude, exercise time, heart rate, chest pain). False positive exercise tests were characterized by markedly downsloping PR segments, greater P wave amplitudes, longer exercise times, and absence of chest pain compared to true positive tests.
Synapse has enriched 10 related papers. Consider them for comparative context: