Why the study?
This study aimed to investigate whether intraoperative transit-time flowmetry values were predictive of graft failure and MACCEs after off-pump coronary artery bypass.
Do transit-time flowmetry values (pulsatility index and flow) predict graft failure and MACCEs in patients undergoing off-pump coronary artery bypass grafting?
Do transit-time flowmetry values (pulsatility index and flow) predict graft failure and MACCEs in patients undergoing off-pump coronary artery bypass grafting?
Answers are grounded in this paper and cite their sources.
A high pulsatility index during intraoperative transit-time flowmetry is a strong independent predictor of major adverse cardiac and cerebrovascular events and graft failure following off-pump coronary artery bypass grafting.
Transit-time flowmetry (TTFM) is commonly used during coronary artery bypass grafting for intraoperative graft assessment. This study aimed to investigate whether TTFM values were predictive of graft failure and major adverse cardiac and cerebrovascular events (MACCEs). Between 2011 and 2018, 1933 patients with 3-vessel coronary artery disease who underwent off-pump coronary artery bypass were retrospectively analyzed. Among them, 1288 sequential venous grafts in 538 consecutive patients were measured using TTFM's 2 parameters, pulsatility index (PI) and flow (mL/min). The anastomoses were divided in the 3 groups depending on the anastomotic site: group A, first side-to-side anastomoses (n = 538), group B; second side-to-side (n = 212), group C; end-to-side (n = 538). MACCEs were related to TTFM. The mean clinical follow-up time was 64.8 ± 21.2 months. Postoperative graft patency was confirmed with multi-slice computed tomography or coronary angiography (follow-up interval: 64.8 ± 50.4 and 27.8 ± 20.5 months based on the date of examination). The 5-year survival rate was 93.7%. The mean graft flow was 59.1 ± 31.3, 41.0 ± 25.2, and 38.9 ± 22.8 mL/minute, and the PI was 2.2 ± 1.3, 2.5 ± 3.4, and 2.4 ± 2.5, in groups A, B, and C, respectively. Graft failure occurred in 23/1055 (2.2%) anastomoses. The 5-year MACCE rate was 6.9% (37/538 patients). Kaplan-Meier analysis revealed that graft patency was significantly lower in low MGF (p = 0.044) and high PI (p < 0.001). Multivariable logistic analysis showed that high PI (>5; HR 2.276; 95%CI 2.188-2.406, p < 0.001) was an independent risk factor for MACCEs. The cutoff values for PI of sequential grafts were 3.65, 3.55, and 3.17 in groups A, B, and C, respectively for the prediction of MACCE. A high PI predicts more predictive poor outcomes of sequential venous grafts after surgery than the low mean graft blood flow.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: