Key result
Short cycle length pacing induces repetitive atrial firing in 100% vs. ~14% during sinus rhythm.
Why the study?
This study evaluated the effect of cycle length on atrial vulnerability in patients manifesting reproducible repetitive atrial firing during atrial extra-stimulus testing.
Does a short cycle length increase atrial vulnerability compared to a long cycle length in patients with repetitive atrial firing?
Does a short cycle length increase atrial vulnerability compared to a long cycle length in patients with repetitive atrial firing?
Decreasing cycle length through atrial pacing potentiates atrial vulnerability by shortening the atrial functional refractory period, which may facilitate paroxysmal atrial fibrillation or flutter.
Answers are grounded in this paper and cite their sources.
Short cycle lengths may heighten atrial vulnerability in repetitive atrial firing; leaves open effects on clinical arrhythmia risk in larger cohorts.
The effect of cycle length on atrial vulnerability was studied in 14 patients manifesting reproducible repetitive atrial firing during atrial extra-stimulus (A2) testing. Repetitive atrial firing was defined as the occurrence of two or more premature atrial responses with return cycle (A2-A3) of 250 msec or less and subsequent mean cycle length of 300 msec or less, following A2. The zone of repetitive atrial firing could be defined in terms of its longest and shortest A1-A2 coupling intervals. Each patient was tested at a long cycle length (CL1) (mean 884 msec) and a short cycle length (CL2) (mean 557 msec). CL1 was sinus rhythm and CL2, an atrial paced rhythm. Repetitive atrial firing occurred in two patients at CL1 and in all patients at CL2. Of the former two patients (group 2), the zone of repetitive atrial firing was markedly widened in one at CL2 due to a shortening of atrial functional refractory period (FRP) at CL2. In the other, zone of repetitive atrial firing could not be totally defined due to induction of sustained atrial flutter preventing definition of atrial FRP. The occurrence of repetitive atrial firing at only CL2 in 12 patients (group 1) reflected: 1) a shortening of atrial FRP from 294 +/- 11 msec at CL1 to 242 +/- 10 msec at CL2 (mean +/- SEM; P less than 0.01), allowing delivery of A2 at shorter coupling intervals (9); 2) the new occurrence of repetitive atrial firing at A1-A2 coupling intervals achievable at both cycle lengths (1); or 3) both effects (2). In conclusion, decrease of cycle length potentiated atrial vulnerability. This demonstration implies that atrial pacing could potentiate occurrence of paroxysmal atrial fibrillation or flutter.
No takes yet. Share an insight, caveat, or question.
Wyndham et al. (1977) studied Atrial vulnerability (reproducible repetitive atrial firing) (n=14). Short cycle length (atrial paced rhythm, mean 557 msec) vs. Long cycle length (sinus rhythm, mean 884 msec) was evaluated on Occurrence of repetitive atrial firing. Short cycle length pacing potentiated atrial vulnerability, inducing repetitive atrial firing in 100% (14/14) of patients compared to 14.3% (2/14) during long cycle length sinus rhythm.
Synapse has enriched 10 related papers. Consider them for comparative context: