INTRODUCTION: Glycated haemoglobin A1c (HbA1c) is the established standard measurement for assessment of glycaemic control in people with diabetes. Here we report on a meta-analysis of real-world observational studies on the impact of flash continuous glucose monitoring on glycaemic control as measured by HbA1c. METHODS: flash glucose monitoring system. RESULTS: Overall mean change in laboratory HbA1c across study subjects at 2-4 months was - 0.55% (95% CI - 0.70, - 0.39). Amongst the 1023 adults, mean change in HbA1c was - 0.56% (95% CI - 0.76, - 0.36); for the 447 children and adolescents, mean change in HbA1c was - 0.54% (95% CI - 0.84, - 0.23). Based on regression analysis, the degree of change in HbA1c correlated with the initial HbA1c of the study population. A longitudinal analysis in adult subjects (n = 1276) shows that HbA1c fell within the first 2 months and changes were sustained up to 12 months. No significant differences were detected between T1D and T2D. CONCLUSION: The meta-analysis reported here confirms that starting the FreeStyle Libre system as part of diabetes care results in a significant and sustained reduction in HbA1c for adults and children with T1D and for adults with T2D. FUNDING: Abbott Diabetes Care.
No takes yet. Share an insight, caveat, or question.
Evans et al. (2019) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: