Answers are grounded in this paper and cite their sources.
Twelve square concrete slabs of 5 ft x 5 ft clear span and fully restrained at the four boundaries were tested to failure. They had a uniform average total thickness of 2 in. and measured 7 ft x 7 ft in overall dimensions. The controlling variable parameter was the variation of the grid reinforcement spacing in the two orthogonal directions, from 8 in. to 3 in., the fiberglass reinforcement area varying from 0.074 sq in./ft to 0.196 sq in./ft in each direction and a reinforcement percentage of 0.290% to 0.769%. In addition, 14 simply supported and two double-span continuous beams were also investigated. They were 5 in. wide and 12 in. deep, with a nominal effective depth of 11.25 in. and center line span of 10 ft 0 in. Analytical expressions were developed for evaluation of crack width, deflection, and limit capacity at failure.
No takes yet. Share an insight, caveat, or question.
Nawy et al. (1977) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: