Key result
Non-contrast BOOST MRI detects acute atrial lesions in only ~63% of PV quadrants versus LGE.
Why the study?
To assess the feasibility of a native 3D T1-weighted BOOST cardiac MRI sequence for detecting acute atrial lesions immediately after RFA without gadolinium contrast administration.
Does non-contrast 3D T1-weighted BOOST cardiac MRI detect acute atrial lesions immediately after radiofrequency ablation in patients with atrial fibrillation?
Observational (n=10)
Does non-contrast 3D T1-weighted BOOST cardiac MRI detect acute atrial lesions immediately after radiofrequency ablation in patients with atrial fibrillation?
Non-contrast 3D T1-weighted BOOST cardiac MRI at 3T can detect acute pulmonary vein antrum lesions immediately after radiofrequency ablation, potentially enabling real-time, gadolinium-free lesion assessment.
Answers are grounded in this paper and cite their sources.
Supports feasibility of gadolinium-free acute lesion imaging post-AF ablation; leaves open prospective validation versus LGE.
To assess the feasibility of a native 3D T1-weighted Bright-blood and black-blOOd phase SensiTive (BOOST) cardiac MRI sequence for detecting acute atrial lesions immediately after radiofrequency ablation (RFA), without gadolinium contrast administration. Ten atrial fibrillation patients underwent 3T cardiac MRI within one hour following RFA. Whole-heart black-blood T1-weighted BOOST and late gadolinium enhanced (LGE) images were acquired during free breathing. Two experienced readers independently assessed the presence and continuity of acute lesions in six predefined pulmonary vein (PV) antrum quadrants per patient. Findings were correlated with procedural RFA parameters. BOOST and LGE sequences detected high signal intensity lesions in all patients, involving both right and left PV antra. BOOST identified acute lesions in 62 and 63% of right and left PV quadrants, respectively, against 100% of quadrants with LGE. Over 80% of LGE-positive quadrants also showed microvascular obstruction. Quadrants with absent or discontinuous BOOST lesions were associated with a significantly greater inter-lesion distance and lower impedance drop during RFA compared to quadrants with continuous lesions. Whole-heart black-blood T1-weighted BOOST cardiac MRI at 3T enables detection of acute PV antrum lesions immediately after RFA without contrast administration. This contrast-free imaging technique may enable real-time, gadolinium-free lesion assessment during or immediately after RFA.
No takes yet. Share an insight, caveat, or question.
Deux et al. (2026) conducted an observational in Atrial fibrillation (n=10). Native 3D T1-weighted BOOST cardiac MRI vs. Late gadolinium enhanced (LGE) MRI was evaluated on Detection of acute atrial lesions in pulmonary vein antrum quadrants. Non-contrast 3D T1-weighted BOOST cardiac MRI detected acute atrial lesions in 62% and 63% of right and left pulmonary vein quadrants, respectively, compared to 100% with late gadolinium enhancement.
Synapse has enriched 10 related papers. Consider them for comparative context: