Why the study?
Coronary microvascular disease is linked to adverse outcomes, but lacks reliable noninvasive quantitative diagnostics, and pressure wire-based IMR has practical restrictions.
Does the quantitative flow ratio-derived index of microcirculatory resistance (QMR) accurately predict microcirculatory function compared to invasive IMR in patients with INOCA?
Does the quantitative flow ratio-derived index of microcirculatory resistance (QMR) accurately predict microcirculatory function compared to invasive IMR in patients with INOCA?
Answers are grounded in this paper and cite their sources.
QMR provides a promising, wire-free alternative to invasive IMR for assessing coronary microvascular function in patients with INOCA.
BACKGROUND: Coronary microvascular disease (CMVD) is associated with adverse cardiovascular outcomes. However, there is no reliable and noninvasive quantitative diagnostic method available for CMVD. The use of a pressure wire to measure the index of microcirculatory resistance (IMR) is possible, but it has inevitable practical restrictions. We hypothesized that computation of the quantitative flow ratio could be used to predict CMVD with symptoms of ischemia and no obstructive coronary artery disease (INOCA). METHODS: We retrospectively assessed the diagnostic efficiency of the quantitative flow ratio-derived index of microcirculatory resistance (QMR) in 103 vessels from 66 patients and compared it with invasive IMR using the thermodilution technique. RESULTS: Patients were divided into the CMVD group (41/66, 62.1%) and non-CMVD group (25/66, 37.9%). Pressure wire IMR measurements were made in 103 coronary vessels, including 44 left descending arteries, 18 left circumflex arteries, and 41 right coronary arteries. ROC curve analysis showed a good diagnostic performance of QMR for all arteries (area under the curve = 0.820, 95% confidence interval 0.736-0.904, p < 0.001) in predicting microcirculatory function. The optimal cut-off for QMR to predict microcirculatory function was 266 (sensitivity: 82.9%, specificity: 72.6%, and diagnostic accuracy: 76.7%). CONCLUSION: QMR is a promising tool for the assessment of coronary microcirculation. The assessment of the IMR without the use of a pressure wire may enable more rapid, convenient, and cost-effective assessment of coronary microvascular function.
No takes yet. Share an insight, caveat, or question.
Gao et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: