Key result
Microcatheter-based alcohol septal ablation matches conventional technique with 100% procedural success.
Why the study?
An alternative microcatheter-based method for alcohol septal ablation is needed when an appropriately sized over-the-wire balloon is unavailable in symptomatic HOCM patients.
Does a microcatheter-based alternative method for alcohol septal ablation provide similar efficacy and safety compared to conventional over-the-wire balloon ablation in patients with symptomatic hypertrophic obstructive cardiomyopathy?
RCT (n=72)
Randomized
Does a microcatheter-based alternative method for alcohol septal ablation provide similar efficacy and safety compared to conventional over-the-wire balloon ablation in patients with symptomatic hypertrophic obstructive cardiomyopathy?
Answers are grounded in this paper and cite their sources.
A microcatheter-based alternative method for alcohol septal ablation is a safe and effective alternative to conventional over-the-wire balloon techniques in patients with symptomatic HOCM.
Objectives Alcohol septal ablation (ASA) is an established treatment for symptomatic hypertrophic obstructive cardiomyopathy (HOCM) aimed at reducing left ventricular outflow tract obstruction. This study evaluated a microcatheter-based alternative method for ASA when an appropriately sized over-the-wire (OTW) balloon is unavailable. Method Between November 2022 and October 2023, 72 symptomatic HOCM patients were recruited and randomized into two groups: conventional ASA using an OTW balloon and an alternative ASA using a microcatheter. In alternative method a microcatheter was placed to the target septal artery and a monorail balloon was then placed in the same septal branch proximal to the tip of the microcatheter. Then the balloon was inflated keeping the proximal end of the balloon placed 2 mm distal to the ostium and then alcohol was injected through the microcatheter after confirming no spillage into Left anterior descending coronary artery. Echocardiographic measurements, procedure times, and complication rates were compared. Results A total of 35 patients underwent conventional ASA, and 32 underwent the microcatheter technique. Patient demographics were similar between groups. Procedural success was 100% in both groups, with no significant differences in total alcohol injected (1.8 ± 0.4 ml vs. 1.8 ± 0.5 ml), immediate post-procedure resting gradients (22.0 ± 7.5 mmHg vs. 21.0 ± 8.0 mmHg), and procedure times (45.8 ± 8.9 min vs. 48.2 ± 7.2 min). Follow-up echocardiography at six months revealed no significant differences in interventricular septal thickness or LV function. Conclusion The microcatheter-based alternative method for ASA is safe and effective in patients with HOCM.
No takes yet. Share an insight, caveat, or question.
Das et al. (2026) conducted an RCT in Hypertrophic obstructive cardiomyopathy (HOCM) (n=72). Alternative alcohol septal ablation using a microcatheter vs. Conventional alcohol septal ablation using an over-the-wire balloon was evaluated on Procedural success. A microcatheter-based alternative method for alcohol septal ablation achieved 100% procedural success, comparable to conventional ablation, with similar procedure times and resting gradients.