Key result
Study evaluates echocardiographic LASi versus CardioMEMS pressures in heart failure, reporting no outcome data yet.
Why the study?
Accurate non-invasive estimation of left atrial pressure in heart failure patients is important but requires validation against invasive or remote monitoring methods.
Does the echocardiographic LA strain indicator (LASi) accurately estimate left atrial pressure compared to a wireless pulmonary artery sensor in patients with heart failure?
Observational (n=38)
Does the echocardiographic LA strain indicator (LASi) accurately estimate left atrial pressure compared to a wireless pulmonary artery sensor in patients with heart failure?
Answers are grounded in this paper and cite their sources.
A novel machine learning-derived echocardiographic parameter (LASi) is being evaluated for non-invasive estimation of left atrial pressure against invasive CardioMEMS measurements in heart failure patients.
Accurate estimation of left atrial pressure (LAP) is an important parameter in the diagnosis, management, and prognostic assessment of patients with heart failure (HF). Left atrial (LA) strain analysis by speckle-tracking echocardiography has showed strong correlation with invasively measured LV end-diastolic pressure.1,2 The LA strain indicator (LASi), a machine learning–derived parameter, incorporates the entire LA strain curve into a single continuous variable ranging from −1 to +1, providing a comprehensive measure of LA mechanics.3 This study evaluated concordance between echocardiographic LASi and a remote monitoring system for HF using a wireless pulmonary artery pressure sensor (CardioMEMS™ System). Thirty-eight patients (mean age 76 ± 8 years, 48% male) with HF and an implanted CardioMEMS™ device underwent paired assessments of LAP using transthoracic echocardiography and simultaneous CardioMEMS™ pressure recordings. The study followed institutional data protection policies and the Declaration of Helsinki; all patients provided informed consent. Echocardiography was performed using standard imaging protocols.4 LA strain was obtained from an LA-focused apical four-chamber view, with strain curves synchronized to the QRS complex. LA reservoir strain was quantified using dedicated software (AutoStrain LA, Ultrasound Workspace; Philips Medical Systems) and a prototype software algorithm that automatically derived the LASi (Figure 1). This parameter is expressed on a continuous scale from −1 to +1, where positive values correspond to left ventricular (LV) end-diastolic pressure (LVEDP) greater or equal to 15 mmHg; negative values are classified to LVEDP < 15 mmHg. Based on prior validation study, LASi values > +0.085 were considered indicative of elevated LAP (≥15 mmHg), values < −0.085 as normal, and those within ±0.085 were regarded as borderline or ‘indeterminate’.5 Indeterminate values were grouped with elevated for analysis to avoid underestimation.
No takes yet. Share an insight, caveat, or question.
Duca et al. (2026) conducted an observational in Heart failure (n=38). Echocardiographic LA strain indicator (LASi) vs. CardioMEMS wireless pulmonary artery pressure sensor was evaluated on Concordance between echocardiographic LASi and CardioMEMS pressure recordings.