Key result
CT-derived geometric orifice area shows excellent reproducibility and correlates strongly with EOA in severe AS.
Why the study?
Does 4D-CT derived geometric orifice area correlate with effective orifice area from echocardiography and catheterization in patients with severe aortic stenosis?
Observational
Does 4D-CT derived geometric orifice area correlate with effective orifice area from echocardiography and catheterization in patients with severe aortic stenosis?
4D-CT derived GOA is a highly reproducible anatomical metric that correlates strongly with physiological valve areas in severe aortic stenosis, offering complementary clinical insight.
Answers are grounded in this paper and cite their sources.
May complement EOA assessment in severe AS; hypothesis-generating pending prospective validation.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Kai et al. (2026) conducted an observational in Severe aortic stenosis. 4D CT-derived geometric orifice area (GOA) vs. Effective orifice area (EOA) was evaluated on Reproducibility of GOA (ICC 0.95). CT-derived geometric orifice area demonstrated excellent reproducibility and correlated strongly with effective orifice area in severe aortic stenosis.
Synapse has enriched 10 related papers. Consider them for comparative context: