The stator insulation breakdown is a major cause of ac machine failures. Ground insulation defaults are easily detected by classical systems based on leakage current measurements, however the turn-to-turn insulation degradations are more difficult to detect. For large machines, on-line methods, based on partial discharge detection and analysis, give good results but they cannot be used for low-voltage machines fed by adjustable speed drives (ASD). This paper presents a new monitoring system able to detect slight variations of high frequency resonances in the winding of a working machine fed by an industrial inverter. The new system works in association with statistical data on accelerated aging of the magnet wire used to build the machine.
No takes yet. Share an insight, caveat, or question.
Perisse et al. (2007) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: