Key result
Dual-lead pacemakers are linked to ~15% more perioperative complications than single-lead devices.
Why the study?
Does dual-lead device implantation increase perioperative complications compared to single-lead devices in patients undergoing new pacemaker or ICD implantation?
Cohort (n=169,547)
Yes
Does dual-lead device implantation increase perioperative complications compared to single-lead devices in patients undergoing new pacemaker or ICD implantation?
Dual-lead pacemakers are associated with a higher risk of perioperative complications compared to single-lead pacemakers, primarily due to lead dislocations, a difference not observed in ICD implantations.
Answers are grounded in this paper and cite their sources.
Higher complications with dual-lead pacemakers warrant caution; hypothesis-generating and requires randomized confirmation.
Background/Objective: Previous studies have indicated a higher incidence of complications associated with dual-lead devices compared to single-lead devices. This retrospective study aimed to investigate the effect of lead count and other factors on peri/postoperative complications for new pacemaker (PM) or implantable cardioverter-defibrillator (ICD) implantations in a representative German cohort. Methods: In accordance with quality assurance (QS) requirements, all hospitals in Germany collect patient-specific data on cardiac device implantation. We utilized the QS database from North Rhine-Westphalia to analyze data from 169,547 patients who underwent PM (n = 137,208) or ICD (n = 32,339) implantation between 2010 and 2014. The primary endpoint was the incidence of perioperative complications in the PM and ICD groups, analyzed separately for single- and dual-lead systems. Regression analysis was performed to identify specific risk factors and the effect of lead number on complications. Results: In the PM group, patients with dual-lead devices experienced significantly more complications than those with single-lead devices (3.27% vs. 2.85%, p < 0.001), largely driven by lead dislocations. In the ICD group, no significant difference in complication rates was observed between single-lead and dual-lead devices (1.39% vs. 1.46%, p = 0.635). The risk of complications was over twice as high for PM implantation compared to ICD implantation (3.17% vs. 1.42%). Patients with intrahospital complications faced a significantly higher risk of mortality than those without complications (PM: 4.5% vs. 1.6%; ICD: 3.9% vs. 0.5%). Independent risk factors for complications and mortality were identified in both groups, with a notable increase in the risk of intrahospital mortality associated with complications. Conclusions: Complications of dual-lead PM implantations are higher than single-lead procedures, mostly due to lead dislocations. Such a difference, though, was not observed in ICD implantations. Our findings may help optimize procedural strategies to improve patient safety, especially in PM implantations.
No takes yet. Share an insight, caveat, or question.
Scholten et al. (2025) conducted a cohort in Pacemaker or implantable cardioverter-defibrillator (ICD) implantation (n=169,547). Dual-lead devices vs. Single-lead devices was evaluated on Incidence of perioperative complications (p=<0.001). Dual-lead pacemaker implantations were associated with more perioperative complications than single-lead devices, while no significant difference was observed for ICDs.