Why the study?
Does cardiac MR-based feature tracking (FT) accurately quantify dyssynchrony compared to velocity encoding cardiac MR (VENC) in healthy volunteers and patients with mechanical dyssynchrony?
Does cardiac MR-based feature tracking (FT) accurately quantify dyssynchrony compared to velocity encoding cardiac MR (VENC) in healthy volunteers and patients with mechanical dyssynchrony?
Cardiac MR-based feature tracking can rapidly appraise left ventricular dyssynchrony from SSFP images, but it is less accurate and reproducible than velocity encoding-based assessment.
Answers are grounded in this paper and cite their sources.
FT may enable rapid LV dyssynchrony assessment from routine cine images; leaves open prospective validation of reproducibility versus VENC before clinical use.
PURPOSE: To investigate whether cardiac magnetic resonance (cardiac MR)-based feature tracking (FT) may be used for robust and rapid quantification of dyssynchrony by measurement of the septal to lateral delay (SLD). MATERIALS AND METHODS: Healthy volunteers (n = 18) and patients with mechanical dyssynchrony (n = 17) were investigated. Velocity encoding cardiac MR (VENC) and steady-state free precession (SSFP)-cine sequences were acquired in identical horizontal long axis (HLA) positions using a 1.5T MR scanner. Using FT and VENC cardiac MR software, myocardial velocity curves were calculated for the basal segment of the septal and lateral wall. Based on the quantity of dyssynchrony, the patients were classified into three subgroups (minimal, intermediate, extensive). SLD and patient classification were compared and intra- as well as interobserver variability assessed. RESULTS: VENC and FT SLD measurements showed strong correlation (r = 0.94) and good agreement (mean 1.33 msec; limits of agreement [LoA] -2.96 to 5.63). Dyssynchrony subclassification based on FT was identical to VENC in 83% of the cases. While FT correctly classified all healthy subjects, three patients with mechanical dyssynchrony were misclassified. Compared to VENC, FT showed higher intra- and interobserver variability. VENC: intraobserver: mean 2.5 msec, LoA -17.5 to 22.5; interobserver: mean 1.5 msec, LoA -17.2 to 21.9. FT: intraobserver: mean 2.1 msec, LoA 27.6 to 31.8; interobserver: mean 2.4 msec LoA -31.4 to 34.5. CONCLUSION: Cardiac MR-based FT analysis may be used for rapid appraisal of left ventricle cardiac dyssynchrony from SSFP images. However, FT results are less accurate and reproducible compared to VENC-based assessment of SLD.
No takes yet. Share an insight, caveat, or question.
Kuetting et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: