Why the study?
Bileaflet mitral valve prolapse has been linked to ventricular arrhythmia and sudden cardiac arrest, but whether left ventricular mechanical dispersion can identify patients at higher arrhythmic risk was unknown.
Does left ventricular mechanical dispersion measured by speckle-tracking echocardiography predict arrhythmic risk in patients with mitral valve prolapse?
Does left ventricular mechanical dispersion measured by speckle-tracking echocardiography predict arrhythmic risk in patients with mitral valve prolapse?
Left ventricular mechanical dispersion measured by speckle-tracking echocardiography is significantly elevated in MVP patients with arrhythmic complications and serves as an independent predictor of arrhythmic risk.
Mechanical dispersion may aid arrhythmic risk assessment in mitral valve prolapse; hypothesis-generating and requires prospective validation.
OBJECTIVE: Bileaflet mitral valve prolapse (MVP) with either focal or diffuse myocardial fibrosis has been linked to ventricular arrhythmia and/or sudden cardiac arrest. Left ventricular (LV) mechanical dispersion by speckle-tracking echocardiography (STE) is a measure of heterogeneity of ventricular contraction previously associated with myocardial fibrosis. The aim of this study is to determine whether mechanical dispersion can identify MVP at higher arrhythmic risk. METHODS: We identified 32 consecutive arrhythmic MVPs (A-MVP) with a history of complex ventricular ectopy on Holter/event monitor (n=23) or defibrillator placement (n=9) along with 27 MVPs without arrhythmic complications (NA-MVP) and 39 controls. STE was performed to calculate global longitudinal strain (GLS) as the average peak longitudinal strain from an 18-segment LV model and mechanical dispersion as the SD of the time to peak strain of each segment. RESULTS: MVPs had significantly higher mechanical dispersion compared with controls (52 vs 42 ms, p=0.005) despite similar LV ejection fraction (62% vs 63%, p=0.42) and GLS (-19.7 vs -21, p=0.045). A-MVP and NA-MVP had similar demographics, LV ejection fraction and GLS (all p>0.05). A-MVP had more bileaflet prolapse (69% vs 44%, p=0.031) with a similar degree of mitral regurgitation (mostly trace or mild in both groups) (p>0.05). A-MVP exhibited greater mechanical dispersion when compared with NA-MVP (59 vs 43 ms, p=0.0002). Mechanical dispersion was the only significant predictor of arrhythmic risk on multivariate analysis (OR 1.1, 95% CI 1.02 to 1.11, p=0.006). CONCLUSIONS: STE-derived mechanical dispersion may help identify MVP patients at higher arrhythmic risk.
No takes yet. Share an insight, caveat, or question.
Ermakov et al. (2019) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: