Current 2-dimensional hepatic model systems often fail to predict chemically induced hepatotoxicity due to the loss of a hepatocyte-specific phenotype in culture. For more predictive in vitro models, hepatocytes have to be maintained in a 3-dimensional environment that allows for polarization and cell-cell contacts. Preferably, the model will reflect an in vivo-like multi-cell type environment necessary for liver-like responses. Here, we report the characterization of a multi-cell type microtissue model, generated from primary human hepatocytes and liver-derived non-parenchymal cells. Liver microtissues were stable and functional for 5 weeks in culture enabling, for example, long-term toxicity testing of acetaminophen and diclofenac. In addition, Kupffer cells were responsive to inflammatory stimuli such as LPS demonstrating the possibility to detect inflammation-mediated toxicity as exemplified by the drug trovafloxacin. Herewith, we present a novel 3D liver model for routine testing in 96-well format capable of reducing the risk of unwanted toxic effects in the clinic.
No takes yet. Share an insight, caveat, or question.
Messner et al. (2012) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: