Why the study?
Acute aortic syndromes in Marfan syndrome often occur before reaching the surgical diameter threshold, highlighting the need for new imaging biomarkers.
Does 4D CMR-derived aortic 3D distensibility and displacement differ between Marfan syndrome patients and healthy volunteers?
Does 4D CMR-derived aortic 3D distensibility and displacement differ between Marfan syndrome patients and healthy volunteers?
Aortic 3D distensibility and displacement derived from 4D CMR are significantly diminished in Marfan syndrome patients compared to healthy volunteers, highlighting their potential as novel imaging biomarkers.
Answers are grounded in this paper and cite their sources.
Supports 3D distensibility as potential Marfan biomarker; leaves open prognostic value and practice change.
BACKGROUND: Acute aortic syndromes in Marfan syndrome (MFS) often occur before reaching the surgical diameter threshold, highlighting the need for new imaging biomarkers. OBJECTIVES: Aim was to compare cardiovascular magnetic resonance (CMR)-derived aortic three-dimensional (3D) distensibility and displacement in MFS patients with or without a history of aortic root surgery (RR or native) and healthy volunteers. METHODS: /∼33ms. A deep learning-based algorithm was used to obtain aorta segmentations. Non-rigid registration of these segmentations was subsequently used to calculate 3D distensibility and its separate components: 2-dimensional distensibility, longitudinal strain, and displacement in the ascending (AAo) and descending aorta (DAo). RESULTS: ) were different for healthy volunteers vs native vs RR patients (AAo: 5.1±1.4 vs 3.6±1.4 vs. 1.4±0.7, p<0.001, DAo: 3.2±1.1 vs. 2.5±0.9 vs 2.4±1.0, p=0.001). Sinotubular junction displacement (mm) was significantly higher for healthy volunteers vs native MFS vs RR MFS patients (10.3±1.3 vs 8.7±2.1 vs 5.7±1.6, p<0.001). In native patients, age (β=-0.06 (95% CI:-0.10 to -0.01), p=0.014) and root diameter (β=-0.1 (95% CI: -0.19 to -0.02), p=0.018) were negatively associated with AAo 3D distensibility, independent of male sex, body surface area, and aortic tortuosity index. CONCLUSION: Aortic 3D distensibility and displacement, derived from 4-dimensional CMR, were significantly diminished in MFS compared to volunteers and should be investigated longitudinally to assess their potential value in predicting aortic events and guiding therapy.
No takes yet. Share an insight, caveat, or question.
Bosshardt et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: