Why the study?
Current 4D flow CMR approaches for thoracic aortic flow are semi-quantitative or reliant on 2D plane placement, needing fully quantitative 3D mapping of abnormal velocity and wall shear stress.
Does a fully quantitative 3D approach using 4D flow CMR correlate with qualitative helicity/vorticity scores and patient characteristics in patients with bicuspid aortic valves?
Does a fully quantitative 3D approach using 4D flow CMR correlate with qualitative helicity/vorticity scores and patient characteristics in patients with bicuspid aortic valves?
A fully quantitative 3D approach using 4D flow CMR can reveal directional abnormalities of velocity and wall shear stress, providing a new tool for hemodynamic characterization in bicuspid aortic valve disease.
Supports quantitative 4D flow CMR metrics in BAV; hypothesis-generating for clinical integration pending validation.
BACKGROUND: Helices and vortices in thoracic aortic blood flow measured with 4D flow cardiovascular magnetic resonance (CMR) have been associated with aortic dilation and aneurysms. Current approaches are semi-quantitative or when fully quantitative based on 2D plane placement. In this study, we present a fully quantitative and three-dimensional approach to map and quantify abnormal velocity and wall shear stress (WSS) at peak systole in patients with a bicuspid aortic valve (BAV) of which 52% had a repaired coarctation. METHODS: ) quantification of abnormally directed velocity and WSS, respectively. Linear regression with Bonferroni corrected significance of P < 0.0125 was used to compare abnormally directed velocity volume and WSS surface in the ascending aorta with qualitative helicity and vorticity scores, with local normalized helicity (LNH) and quantitative vorticity and with patient characteristics. RESULTS: The velocity volumes > 120° correlated moderately with the vorticity scores (R ~ 0.50, P < 0.001 for both observers). For WSS surface these results were similar. The velocity volumes between 60° and 120° correlated moderately with LNH (R = 0.66) but the velocity volumes > 120° did not correlate with quantitative vorticity. For abnormal velocity and WSS deviating between 60° and 120°, moderate correlations were found with aortic diameters (R = 0.50-0.70). For abnormal velocity and WSS deviating > 120°, additional moderate correlations were found with age and with peak velocity (stenosis severity) and a weak correlation with gender. Ensemble maps showed that more than 60% of the patients had abnormally directed velocity and WSS. Additionally, abnormally directed velocity and WSS was higher in the proximal descending aorta in the patients with repaired coarctation than in the patients where coarctation was never present. CONCLUSION: The possibility to reveal directional abnormalities of velocity and WSS in 3D provides a new tool for hemodynamic characterization in BAV disease.
No takes yet. Share an insight, caveat, or question.
Ooij et al. (2021) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: