Why the study?
Preoperative echocardiographic assessment is critical for severe degenerative mitral regurgitation, prompting a comparison of 3D TTE versus 3D TEE accuracy against surgical findings and an evaluation of whether 3D TTE alone offers comprehensive evaluation.
Does 3D TTE provide comparable diagnostic accuracy to 3D TEE for identifying valvular lesions and annular dimensions in patients with severe degenerative mitral regurgitation?
Does 3D TTE provide comparable diagnostic accuracy to 3D TEE for identifying valvular lesions and annular dimensions in patients with severe degenerative mitral regurgitation?
3D TTE provides comparable diagnostic accuracy to 3D TEE for identifying diseased scallops and static annular parameters in severe degenerative mitral regurgitation, though it is less accurate for detecting multiple chordal ruptures.
Answers are grounded in this paper and cite their sources.
3D TTE may support scallop assessment in degenerative MR; leaves open its reliability versus TEE for multiple chordal ruptures.
BACKGROUND: Preoperative echocardiographic assessment is critical for patients with severe degenerative mitral regurgitation to ensure personalized surgical mitral valve repair. This study aimed to compare the diagnostic accuracy of three-dimensional transthoracic echocardiography (3D TTE) and three-dimensional transesophageal echocardiography (3D TEE) in identifying valvular lesions, using surgical findings as the reference. Additionally, we evaluated whether annular dimensional parameters derived from TTE and TEE, using dedicated 3D software, could confirm whether 3D TTE alone offers a comprehensive preoperative evaluation. METHODS: We enrolled 60 patients with severe organic mitral regurgitation scheduled for surgical valve repair. Each patient underwent preoperative 3D TTE, intraoperative 3D TEE prior to surgery, followed by annuloplasty. Mitral valve reconstructions from both TTE and TEE were compared, and dedicated 3D software (EchoPAC GE-Health-Care Software 3D-auto-MVQ) was employed to reconstruct annular geometries from both methods. RESULTS: Both 3D TTE and 3D TEE demonstrated comparable accuracy in identifying diseased scallops (overall accuracy: 3D TTE 91.8%, 3D TEE 98.1%, p > 0.05). However, 3D TTE was inferior to 3D TEE in identifying multiple chordal ruptures (accuracy: 3D TTE 80%, 3D TEE 100%). Quantitative analysis of the mitral annulus revealed that 3D TTE and 3D TEE yielded overlapping results for static parameters (p > 0.05), whereas dynamic parameters differed significantly (p < 0.05). CONCLUSIONS: In the selected population, 3D TTE demonstrated diagnostic accuracy comparable to transesophageal echocardiography in identifying mitral valve lesions. Furthermore, with the use of dedicated 3D software, TTE alone may provide a comprehensive and noninvasive preoperative evaluation, particularly for static annular parameters. Further studies are warranted to corroborate these findings.
No takes yet. Share an insight, caveat, or question.
Fioretti et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: