Why the study?
What are the risk factors for extension of dissection following endovascular repair of type B aortic dissection?
What are the risk factors for extension of dissection following endovascular repair of type B aortic dissection?
Answers are grounded in this paper and cite their sources.
Careful examination of aortic wall anatomy and cautious intraprocedural device manipulation are crucial to minimize the risk of iatrogenic dissection extension during endovascular repair of type B aortic dissection.
Endovascular treatment is becoming the most important treatment modality in the complex management of type B dissection, providing benefits to both acute and chronic patients. Growing technical experience and improving stent-graft devices have resulted in better patient outcome and expanded clinical indications. Nevertheless, similar to any treatment option, this less invasive method has its inherent risks. Several cases of iatrogenic dissection have been reported in the literature, underlying the need for guidelines to minimize this risk and improve procedural safety. Extension of the dissection after endovascular repair of type B dissection does not appear to be device-specific, but related primarily to aortic wall alterations or adverse anatomy that arise most frequently in hypertensive patients or those with challenging aortic configuration. An accurate examination of the aortic wall and dissection anatomy and careful intraprocedural device manipulation and balloon molding may help avoid this potentially life-threatening complication.
No takes yet. Share an insight, caveat, or question.
Fattori et al. (2005) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: