Answers are grounded in this paper and cite their sources.
OBJECTIVES: Point-of-care ultrasound (POCUS) has become an integral diagnostic and interventional tool. Barriers to POCUS training persist, and it continues to remain heterogeneous across training programs. Structured POCUS assessment tools exist, but remain limited in their feasibility, acceptability, reliability, and validity; none of these tools are entrustment-based. The objective of this study was to derive a simple, entrustment-based POCUS competency assessment tool and pilot it in an assessment setting. METHODS: = 37) performance on a simulated FAST examination. The intraclass correlation (ICC) for inter-rater reliability and Cronbach's alpha for internal consistency were calculated. A statistical analysis was performed to compare the UCAT to other competency surrogates. While UCAT scores were not impacted by level of training, they were significantly impacted by the number of previous POCUS studies completed. CONCLUSIONS: We developed and successfully piloted the UCAT, an entrustment-based bedside POCUS competency assessment tool suitable for rapid deployment. The findings from this study indicate early validity evidence for the use of the UCAT as an assessment of trainee POCUS competence on FAST. The UCAT should be trialed in different populations performing several POCUS study types.
No takes yet. Share an insight, caveat, or question.
Bell et al. (2020) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: