Why the study?
Increasing use of TMVr has led to recurrent MR cases, confronting surgeons with challenges regarding how to explant devices and whether to repair or replace the valve.
Can transcatheter edge-to-edge repair devices be surgically explanted without damaging the mitral valve leaflets using tailored minimally invasive techniques?
Can transcatheter edge-to-edge repair devices be surgically explanted without damaging the mitral valve leaflets using tailored minimally invasive techniques?
Transcatheter edge-to-edge repair devices can be surgically explanted without damaging the mitral valve leaflets using specific techniques tailored to the device and degree of encapsulation.
Answers are grounded in this paper and cite their sources.
Alternative explantation techniques may aid select failed TMVr cases; leaves open need for prospective validation before wider use.
Objective: The use of transcatheter mitral valve repair (TMVr) devices is increasing in elderly and high-risk patients. However, the increasing number of patients with recurrent mitral regurgitation (MR) has confronted surgeons with the issue of how to explant the devices and whether the mitral valve should be repaired or replaced. The aim of the study is to summarize our clinical experience with the explantation of different TMVr devices and to provide alternative surgical techniques that can be performed in different clinical scenarios. Methods: A simulator system including a dummy valve representing native valves was used to create video documentation and to develop alternative surgical methods for clip explantation. Moreover, the clip explantation techniques were shown in 2 patients undergoing minimally-invasive mitral valve repair after a failed TMVr. Results: Alternative explantation techniques were described for each TMVr device; 2 techniques for MitraClip and 3 techniques for PASCAL (Precision Transcatheter Valve Repair System), which may be adjusted for each individual according to the underlying valve pathology and the degree of device encapsulation. The patients were discharged without residual MR and remained MR free at the follow-up. Conclusions: Transcatheter edge-to-edge repair devices can be surgically explanted without damaging the MV leaflets. Removal of each device may require a different technique tailored to the degree of device encapsulation and valve pathology. Increasing experience may facilitate repair in patients with recurrent MR after TMVr.
No takes yet. Share an insight, caveat, or question.
Akansel et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: