Key result
Unattended automated office BP yields similar systolic values to attended measurement using identical protocols.
Why the study?
It remained uncertain whether unattended automated OBP differs from standardized attended automated OBP when performed using the same device and measurement protocol.
Does unattended automated office blood pressure measurement differ from attended automated office blood pressure measurement in blood pressure values?
Meta-Analysis (n=1,004)
Does unattended automated office blood pressure measurement differ from attended automated office blood pressure measurement in blood pressure values?
Effect estimate: Mean difference -1.3 mm Hg (95% CI -4.3, 1.7)
Absolute Event Rate: 133.9% vs 135.3%
p-value: p=NS
Attended automated office blood pressure provides similar blood pressure values as unattended automated office blood pressure when the same device and measurement protocol are used.
Supports interchangeable attended or unattended automated office BP use; confirms similarity when device and protocol are standardized.
There is increasing interest in unattended automated office blood pressure (OBP) measurement, which gives lower blood pressure values than the conventional auscultatory OBP. Whether unattended automated OBP differs from standardized attended automated OBP performed using the same device and measurement protocol remains uncertain. A systematic review and meta-analysis of studies (aggregate data) comparing unattended vs attended automated OBP using the same device and measurement protocol (conditions, number of measurements, visits) was performed. Ten eligible studies (n = 1004, weighted age 60.8 ± 4.2 [SD] years, 55% males) were analyzed. Unattended OBP (pooled systolic/diastolic 133.9 [95% CI: 129.7, 138]/80.6 [95% CI: 77, 84.2] mm Hg) did not differ from attended OBP (135.3 [95% CI: 130.9, 139.6]/81 [95% CI: 77.6, 84.3] mm Hg); pooled systolic OBP difference -1.3, 95% CI: -4.3, 1.7 mm Hg and diastolic -0.4, 95% CI: -1.2, 0.3 mm Hg. Nine of ten studies achieved high quality score and no publication bias was identified. Meta-regression analysis did not reveal any effect of age, gender, or attended systolic OBP on the unattended-attended systolic OBP difference (P = NS for all). However, there was a trend toward higher attended than unattended OBP at higher OBP levels. These data suggest that, when the same device and measurement protocol are used, attended automated OBP provides similar blood pressure values as unattended automated OBP. Although unattended automated OBP is theoretically advantageous as it ensures that standardized conditions and measurement protocol are used, attended automated OBP, if carefully performed, appears to be a reasonable and practical alternative.
No takes yet. Share an insight, caveat, or question.
Κόλλιας et al. (2018) conducted a meta-analysis in Blood pressure measurement (n=1,004). Unattended automated office blood pressure vs. Attended automated office blood pressure was evaluated on Mean difference in systolic office blood pressure (Mean difference -1.3 mm Hg, 95% CI -4.3, 1.7, p=NS). Unattended automated office blood pressure provided similar systolic values compared to attended measurement when using the same device and protocol (mean difference -1.3 mm Hg).