Key result
PASTEC platform for structured annotation is linked to ~2 seconds longer processing time per transmission.
Why the study?
Cardiac implantable electronic device remote monitoring generates substantial workload, but lack of infrastructure for prospective data aggregation and evaluation limits clinical translation of artificial intelligence.
Does the PASTEC platform enable efficient data aggregation and annotation during routine cardiac remote monitoring compared to standard review?
Observational (n=1,276)
No
Does the PASTEC platform enable efficient data aggregation and annotation during routine cardiac remote monitoring compared to standard review?
The PASTEC platform provides a secure, scalable infrastructure for AI validation in cardiac remote monitoring with minimal impact on routine clinical workflow.
Answers are grounded in this paper and cite their sources.
Annotation adds limited time to RM review; leaves open whether open platforms enable scalable AI integration.
Remote monitoring (RM) of cardiac implantable electronic devices generates large volumes of data that must be reviewed using vendor-specific platforms, creating a growing clinical workload. Although artificial intelligence (AI) could alleviate this burden, the absence of infrastructures enabling prospective data aggregation and evaluation within routine workflows limits clinical translation. We developed PASTEC, an open platform integrated into existing RM systems via a browser extension, enabling client-side pseudonymization, annotation, and centralized academic data storage. Platform usability was prospectively evaluated during one week of routine activity in a high-volume RM center and compared with a week of standard RM review. A total of 1276 recordings were reviewed, including 697 with structured annotation. Median processing time per recording was 5.31 s with annotation versus 2.88 s without annotation (p < 0.01), corresponding to a limited additional workload compatible with routine clinical activity. No identifiable patient information was detected in reviewed pseudonymized data. PASTEC provides a scalable infrastructure addressing a key bottleneck in the prospective clinical validation of AI for cardiac remote monitoring.
No takes yet. Share an insight, caveat, or question.
Sacristan et al. (2026) conducted an observational in Cardiac implantable electronic devices (CEIDs) remote monitoring (n=1,276). PASTEC platform with active structured annotation vs. Standard remote monitoring review without annotation was evaluated on Time required to complete the review of an episode (time-to-completion) (Absolute difference 2.43 seconds, p=<0.001). The PASTEC platform enabled prospective structured annotation of cardiac remote monitoring data, increasing median processing time per transmission by 2.43 seconds compared to standard review.