Compares noise transfer effects in office buildings with neoprene isolation, suggesting improved acoustics.
Office buildings with lightweight concrete on metal deck are commonly built with cementitious raised access flooring used for pressurized HVAC or other utilities. Typical modern designs for open office work environments have exposed metal deck structure without dropped s. A recent San Francisco project included a proposed noisy space intended for simultaneous use with a quiet open office environment on the floor below. The project design and construction team settled on an approach to provide neoprene waffle pads at the pedestal supports for the raised access floor. Prior to construction, resonance acoustics (RA) visited the project to measure the noise transfer between the two floors, with standard raised access flooring installed. In this presentation, RA will present the pre- and post-construction comparison of test results as well as discuss noise transfer testing methodology for large open spaces.
No takes yet. Share an insight, caveat, or question.
Peter Holst (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: