Answers are grounded in this paper and cite their sources.
Older adults experience the deleterious health effects of extreme heat events at a greater rate than any other age cohort. Indoor cooling with an air conditioner remains the most effective strategy to prevent such adverse health effects. However, approximately 1 in 8 Americans do not have in-home air conditioners, and power outages threaten region-wide access to air conditioning at times when it is most needed. Thus, there is a clear need to identify low-energy cooling strategies to attenuate excessive elevations in core temperature and accompanying cardiovascular strain in older adults during extreme heat conditions. We hypothesized that supplemental skin wetting via water spray and electrical fan use would attenuate elevations in core temperature and cardiovascular strain in older adults exposed to hot and humid heat. Further, we tested whether a combination of skin wetting and fan use could synergistically attenuate thermal and cardiovascular strain. Seventeen older adults (8 F; 71±5 yrs) were exposed to 3-hours of ambient heating, replicating peak environmental conditions of the 1995 Chicago heat wave (41ºC, 40% rh), with or without (control) skin-wetting via tap temperature water (~40 g applied every 10-minutes), fan use (~2.5 m/s), or a combination of skin-wetting and fan use. To simulate heat generation associated with activities of daily living, participants performed six 5-min bouts of light cycling (~3 METs) dispersed throughout the heat exposure. We assessed the change in core and skin temperatures, whole-body sweat rate, heart rate, and rate pressure product. We analyzed data using one-way repeated measures ANOVA with Dunnett tests to compare responses against the control trial. The increase in core temperature was not affected by water spray (0.78±0.29°C; p=0.43), or water spray + fan (0.78±0.27°C; p=0.06), compared to control (0.86±0.25°C); however, fan only use augmented the increase in core temperature (1.08±0.46°C; p=0.03). When compared to control (2.3±1.4°C), the change in skin temperature was reduced with water spray (0.74±0.77°C; p< 0.001) and water spray + fan (0.59±1.9°C; p< 0.01) but augmented with fan alone (3.2±1.0°C; p=0.01). Further, whole-body sweat rate was attenuated with water spray (0.20±0.07 L/h; p< 0.001) but increased with fan (0.45±0.10 L/h; p< 0.001) and water spray + fan (0.36±0.10 L/h; p=0.001) compared to control (0.32±0.10 L/h). There was no difference in heart rate or rate pressure product between control and cooling modalities (all p ≥ 0.05). These data suggest that supplemental skin-wetting via water spray does not attenuate thermal (core temperature) or associated cardiovascular strain (heart rate and pressure product), whereas electric fan use augments thermal but not cardiovascular strain, of older adults exposed to hot and humid conditions with accompanying activities of daily living. Further, these data highlight the importance of identifying environment-specific cooling modalities. Supported by NIH Grant R01AG069005 (CGC) This abstract was presented at the American Physiology Summit 2026 and is only available in HTML format. There is no downloadable file or PDF version. The Physiology editorial board was not involved in the peer review process.
No takes yet. Share an insight, caveat, or question.
Cottle et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: