Evaluates non-contact elasticity measurement in fruit quality control, suggesting potential improvements.
To improve fruit quality control, we developed a non-contact elasticity measurement system that uses airborne ultrasound and an offset parabolic reflector. To miniaturize the system, a 100-kHz circular stepped-plate transducer (CSPT) was designed and evaluated. The CSPT consists of a bolt-clamped Langevin transducer (BLT) and stepped plate. Based on the modal analysis, the CSPT was designed to resonate at 100 kHz. The diameter and length of the BLT were 10 and 50 mm, respectively. The diameter and step height of the stepped plate were 50 and 1.7 mm, respectively. The resonance frequency and Q-factor of the CSPT fabricated by machining were 100.4 kHz and 110.4, respectively. The beam emitted from the stepped plate was focused using a parabolic reflector. The focused beam width was 5.2 mm, and the acoustic radiation force (ARF) was 0.07 μN (@150 V0-p). To evaluate the elasticity measurement system with the CSPT, the vibration produced by the ARF was detected using a laser Doppler velocimeter. The displacements of the rubber samples with hardnesses of A30, A50, and A70 were 1.5, 0.76, and 0.24 nm, respectively. The trend that displacement decreased as stiffness increased is consistent with the Voigt model, showing the potential for non-contact elastic measurement.