Figure 1. Main study findings. P values in panel B were derived from pairwise χ2 tests with Holm correction. * Percentages were calculated considering the number of patients who underwent a redo procedure. ** Among the seven patients receiving CTI ablation in Group-A, RF energy alone with 8 mm linear catheters was used in five cases (71%). PFA alone was used at all other LA/RA sites in Group-A and Group-B. † In Group-C, among the 45 (92%) patients who received RF ablation combined with PFA, the median number of RF applications was 11 (6–18). Among the 37 patients who underwent posterior–lateral MI ablation in Group-C, 25 (68%) received RF in combination with PFA in the region, with RF specifically applied at the lateral MI; one patient (3%) underwent ablation of the lateral MI using RF alone. ‡ Among the 21 patients who underwent CTI ablation in Group-C, 20 (95%) received RF alone, whereas the remaining patient (5%) underwent CTI ablation using PFA alone. § Among the 40 patients who underwent LA anterior wall ablation in Group-C, 29 (73%) received RF applications close to the MV, with PFA delivered at LA anterior wall sites distant from the MV. || Among the seven patients who underwent LAA…