Background: Pedicle screw instrumentation of the cervical spine, although technically challenging due to the potential risk of serious neurovascular injuries, is biomechanically favorable for stabilization purposes. Patient-specific templates are increasingly used in the thoracolumbar spine with excellent accuracy. The aim of this study was to evaluate the accuracy of cervical pedicle screw placement with patient-specific templates in a clinical setting and to report the European experience so far. Methods: Multicentric, retrospectively obtained data of twelve patients who underwent dorsal instrumentation of the cervical spine with 3D-printed patient-specific templates were analyzed. Postoperative computed tomography (CT) scans were used to evaluate pedicle perforation and screw deviations between the planned and actual screw position. Furthermore, surgical time, radiation exposure, blood loss and immediate postoperative complications were analyzed. Overall complications were one adjacent segment kyphosis, one transient C5 palsy and one wound healing disorder. Conclusion: Patient-specific 3D-printed templates provide a highly accurate option for placing cervical pedicle screws for dorsal instrumentation of the cervical spine.
No takes yet. Share an insight, caveat, or question.
Farshad et al. (2022) studied this question.