Key result
CARTONET R14 deep learning model improves sensitivity to ~78% vs R12.1.
Why the study?
The CARTONET R14 model uses deep learning for CARTO ablation analysis, but its accuracy and positive predictive value remain underevaluated.
Does the CARTONET R14 model improve sensitivity and PPV for ablation site classification compared to the R12.1 model in atrial fibrillation ablation cases?
Observational (n=396)
Does the CARTONET R14 model improve sensitivity and PPV for ablation site classification compared to the R12.1 model in atrial fibrillation ablation cases?
The deep learning-based CARTONET R14 model significantly improves sensitivity and positive predictive value for ablation site classification compared to the previous R12.1 model.
Answers are grounded in this paper and cite their sources.
May support R14 integration for AF ablation planning; leaves open need for prospective outcome validation.
BACKGROUND: CARTONET is a cloud-based system for the analysis of ablation procedures using the CARTO system. The current CARTONET R14 model employs deep learning, but its accuracy and positive predictive value (PPV) remain underevaluated. OBJECTIVE: This study aimed to compare the characteristics of the CARTONET system between the R12.1 and the R14 models. METHODS: Data from 396 atrial fibrillation ablation cases were analyzed. Using a CARTONET R14 model, the sensitivity and PPV of the automated anatomic location model were investigated. The distribution of potential reconnection sites and confidence level for each site were investigated. We also compared the difference in the data between the CARTONET R12.1, the previous CARTONET version, and the CARTONET R14 models. RESULTS: We analyzed the overall tags of 39,169 points and the gap prediction of 625 segments using the CARTONET R14 model. The sensitivity and PPV of the R14 model significantly improved compared with the R12.1 model (R12.1 vs R14: sensitivity, 71.2% vs 77.5% [P < .0001]; PPV, 85.6% vs 86.2% [P = .0184]). The incidence of reconnections was highly observed in the posterior area of the right pulmonary veins (98/238 [41.2%]) and left pulmonary veins (190/387 [49.1%]). In contrast, the possibility of reconnection was highest in the roof area for the right pulmonary veins (14% [5.5%-41%]) and left pulmonary veins (16% [8%-22%]). CONCLUSION: The R14 model significantly improved sensitivity and PPV compared with the R12.1 model. The tendency for predicting potential reconnection sites was similar to that of the previous version, the R12 model.
No takes yet. Share an insight, caveat, or question.
Narita et al. (2025) conducted an observational in Atrial fibrillation (n=396). CARTONET R14 model vs. CARTONET R12.1 model was evaluated on Sensitivity of the automated anatomic location model (p=< .0001). The CARTONET R14 deep learning model improved sensitivity and positive predictive value compared with the R12.1 model.
Synapse has enriched 10 related papers. Consider them for comparative context: