Key result
Band-pass filters (1.0-100 Hz and 2.0-100 Hz) provided the best combinations of fetal signal detection rates, SNR, and SDR for both shielded and unshielded fetal magnetocardiography.
Population
66 fetal magnetocardiography (fMCG) datasets at gestational ages 22-37 weeks
Design
Other
Authors
Loading...
May enhance fMCG signal quality in practice; leaves open prospective clinical validation.
Band-pass filters of 1.0-100 Hz and 2.0-100 Hz optimize signal quality in both shielded and unshielded fetal magnetocardiography, with 1.0-100 Hz preferred for arrhythmic fetuses.
Comani et al. (2005) studied Fetal magnetocardiography (n=66). Band-pass filters (1.0-100 Hz and 2.0-100 Hz) vs. Other filter settings was evaluated on Fetal signal detection rates, signal-to-noise ratio (SNR), and signal-to-distortion ratio (SDR). Band-pass filters (1.0-100 Hz and 2.0-100 Hz) provided the best combinations of fetal signal detection rates, SNR, and SDR for both shielded and unshielded fetal magnetocardiography.